Force Gauge for Testing Fasteners, Hooks and Lifting Components Malaysia
Force Gauge for Testing Fasteners, Hooks and Lifting Components Malaysia
Fasteners, hooks and load-bearing components must be able to withstand the forces expected during assembly or use. Manufacturers and quality-control teams may therefore need to measure pull-out force, retention force, deformation force or breaking force.
The Landtek FM-207-500K Digital Force Gauge measures push and pull force up to:
±500 kgf
±4900 N
±1100 lbf
Its external force sensor can be incorporated into a suitable test stand or customised fixture for industrial component testing in Malaysia.
What Components Can Be Evaluated?
Depending on their size and expected load, the FM-207-500K may be used to evaluate:
Hooks
Bolts and screws
Rivets
Clips and retaining parts
Anchors
Buckles
Shackles
Brackets
Pins
Handles
Latches
Wire loops
Small load-bearing assemblies
Mechanical connection points
The instrument’s suitability depends on the required force, fixture design and testing procedure.
What Types of Force Tests Can Be Performed?
Pull-Out Force Test
A pull-out test measures the force required to remove a fastener, anchor, insert or connected component from its installed position.
Examples include:
Pulling an insert from a plastic component
Testing an anchor installed in a sample material
Measuring the extraction force of a pin
Checking whether a hook remains attached
Testing a press-fit component
The result can help identify weak connections, poor installation or inconsistent production.
Retention-Force Test
A retention test confirms whether a component remains secured under a specified pulling load.
Unlike a destructive test, the component may only need to withstand a defined force for a certain duration.
Real-time mode allows the operator to monitor the applied force and maintain it near the required value.
Deformation Test
Some components must not bend, open or permanently deform below a specified load.
During this test, the operator gradually applies force while observing:
Applied force
Visible deformation
Permanent shape change
Movement at the connection point
Failure of the supporting material
The force value should be recorded together with the type of deformation observed.
Breaking-Force Test
A breaking-force test continues until the component, joint or supporting material fails.
Peak-value mode records the highest force reached before failure.
The test may help compare:
Different materials
Alternative component designs
Suppliers
Production batches
Manufacturing processes
Destructive tests require appropriate guarding because broken parts may release suddenly.
Why Use an External Force Sensor?
For higher-force testing, a separate sensor provides more installation flexibility than a small handheld meter.
The FM-207-500K sensor can be:
Mounted to a test frame
Connected to a pulling mechanism
Installed in a compression fixture
Positioned close to the component
Integrated into a customised testing setup
The display can remain in a more convenient viewing position while the sensor measures force at the test point.
The applied force must remain aligned with the sensor. Twisting, bending and side loading should be avoided.
Example: Hook Pull Test
A hook pull test may be used to measure:
The force required to straighten or open the hook
The pull-out strength of its mounting point
The load at which the hook breaks
Whether the hook can withstand a specified proof load
A typical setup includes:
A rigid test frame
A suitable external force sensor
A connection between the sensor and hook
A secure mounting point for the test sample
A controlled pulling mechanism
A protective guard
The exact procedure depends on the hook design and applicable specification.
Example: Fastener Pull-Out Test
A fastener pull-out test evaluates the force required to remove a screw, bolt, rivet, insert or anchor from a sample.
Before testing, define:
Fastener type and dimensions
Base material
Installation depth
Installation method
Pulling direction
Loading speed
Maximum required load
Pass or fail criterion
All samples should be prepared consistently. Otherwise, variations in installation may affect the result more than the fastener itself.
How to Set Up the Test
1. Define the Test Objective
Decide whether the test is intended to measure:
Proof load
Pull-out force
Retention force
Deformation force
Breaking force
Compression force
The objective determines the fixture, measurement mode and stopping point.
2. Confirm the Expected Force
The expected force must fall within the useful range of the FM-207-500K.
For much smaller forces, a lower-capacity gauge may provide better measurement resolution. Tests that may exceed 500 kgf require a higher-capacity system.
3. Select the Correct Fixture
The fixture must hold the component without introducing unwanted bending or slippage.
Possible fixtures include:
Clevis connections
Pulling hooks
Clamps
Threaded adapters
Mounting plates
Compression plates
Custom-machined holders
All fixture components must have an adequate rated capacity.
4. Align the Sensor
The sensor, fixture and component should follow the same force axis.
Incorrect alignment may cause:
Unstable readings
Uneven loading
Premature component failure
Damage to the sensor
Poor test repeatability
5. Zero the Instrument
After installing the sensor and fixture, remove any unintended load and set the display to zero.
A stable zero reading should be confirmed before every test.
6. Select the Measurement Mode
Use real-time mode for:
Applying a proof load
Holding a component at a specified force
Observing gradual deformation
Adjusting an assembly
Use peak mode for:
Pull-out testing
Breaking-force testing
Maximum retention-force testing
Destructive testing
7. Apply the Force Gradually
Apply force smoothly and avoid shock loading.
Stop the test if:
The required load is reached
The component fails
The fixture slips
The sensor becomes misaligned
The overload warning activates
The test frame becomes unstable
8. Document the Result
A useful test record may include:
Component description
Material
Sample identification
Fixture used
Test direction
Maximum force
Measurement unit
Loading method
Failure mode
Pass or fail result
Operator and test date
The FM-207-500K can store up to 99 measurement records for later review.
Proof Load Is Not the Same as Breaking Load
A proof-load test checks whether a component can withstand a specified load without unacceptable damage.
A breaking-load test determines the force at which it fails.
These two results should not be treated as interchangeable.
A component with a measured breaking force of 400 kgf should not automatically be assigned a safe working load of 400 kgf. Safety factors, material behaviour, repeated loading, environmental conditions and applicable standards must also be considered.
Important Limitation for Lifting Components
The FM-207-500K can measure force during product development, internal quality checks and comparative testing.
However, testing regulated lifting accessories may require:
A higher-capacity calibrated test machine
Traceable calibration
A controlled loading rate
A specified proof load
Accredited inspection
Compliance with a recognised standard
Formal test documentation
The use of a force gauge alone does not automatically certify a hook, shackle or lifting accessory as safe for lifting.
The required standard and certification scope should be confirmed before conducting the test.
Common Testing Errors
Fixture Is Weaker Than the Test Sample
The fixture may bend or fail before the component reaches its expected load.
Force Is Applied at an Angle
Angular loading can produce bending and inconsistent results.
Different Samples Are Installed Differently
Variations in installation depth, torque or alignment can affect pull-out results.
Load Is Applied Too Quickly
Sudden loading may create an impact force and an artificially high peak.
Only the Force Value Is Recorded
The failure mode is also important. A fastener pulling out is different from the fastener itself breaking.
Maximum Range Is Treated as a Working Load
The instrument’s maximum measuring range should not be exceeded or routinely treated as the ideal everyday testing point.
Frequently Asked Questions
Can the FM-207-500K test hooks?
Yes, when the expected force is within 500 kgf and a suitable test frame, fixture and safety guard are used.
Can it test bolts and anchors?
It can measure pull-out or tensile force when the sample and sensor are installed in an appropriate fixture.
Can it certify lifting hooks?
Not by itself. Formal certification may require a prescribed test machine, accredited procedure and specific documentation.
Can it measure compression force?
Yes. It supports both tension and compression measurement when correctly installed.
Can it capture the maximum force before failure?
Yes. Peak-value mode records the highest force reached during the test.
Does it include all required fixtures?
Specialised fixtures are selected according to the component. Confirm the supplied accessories and arrange custom fixtures where necessary.
Select the Correct Component-Testing System in Malaysia
Before selecting a force gauge, send MTM Precision:
Component photo and dimensions
Material and mounting method
Expected test force
Pull or compression requirement
Proof or destructive test requirement
Applicable standard
Required fixture
Number of tests per day
Calibration and documentation requirements
MTM Precision can help evaluate whether the Landtek FM-207-500K is appropriate for the intended internal testing application.
Contact MTM Precision
MTM Precision Sdn. Bhd. (744811-A)
Telephone: +603-8080 7172
WhatsApp: +6019-665 7346 / +6016-660 7346
Email: mtmpre@yahoo.com / enquiry@mtmpre.com.my
Website: www.mtmpre.com.my
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar Lapan Belas,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Supply and technical support are available throughout Malaysia, including Selangor, Kuala Lumpur, Johor, Penang, Perak, Melaka, Negeri Sembilan, Pahang, Kedah, Perlis, Terengganu, Kelantan, Sarawak and Sabah.
16 Sep 2026