How to Perform a Breaking Force Test with the Landtek FM-207-500K Malaysia
How to Perform a Breaking Force Test with the Landtek FM-207-500K Malaysia
A breaking-force test determines the maximum force a product, material or connection can withstand before it breaks, separates, slips or permanently fails.
The Landtek FM-207-500K Digital Force Gauge measures tension and compression force up to:
±500 kgf
±4900 N
±1100 lbf
Its peak-value function captures the highest force reached during the test, while its external sensor can be installed on a suitable high-capacity test stand or customised fixture.
What Is Breaking Force?
Breaking force is the maximum measured force reached before a sample fails.
Failure does not always mean that the sample breaks into two pieces. Depending on the product, failure may occur when:
A cable snaps
A wire pulls out of a terminal
A bonded joint separates
A hook opens or deforms
A fastener pulls out
A clip releases
A rope begins to slip
A plastic component cracks
An assembly separates
A compression sample collapses
The maximum force and the observed failure mode should both be recorded.
Why Perform a Breaking-Force Test?
Manufacturers and quality-control teams use breaking-force tests to:
Compare different materials
Evaluate product designs
Check production consistency
Compare alternative suppliers
Investigate customer complaints
Determine the weakest component
Verify internal quality requirements
Monitor changes after a process adjustment
Support research and development
The test can reveal whether a product fails at the intended point or at an unexpected connection.
Products That May Be Tested
Depending on their size and expected breaking force, possible samples include:
Cables and wires
Rope and straps
Hooks and clips
Fasteners
Terminals and connectors
Bonded components
Plastic parts
Mechanical assemblies
Handles and latches
Springs
Packaging components
Construction hardware
The expected breaking force must remain within the FM-207-500K measuring range.
Breaking Force vs Proof Load
These terms describe different tests.
Breaking-Force Test
The load is increased until the sample fails. The sample is usually damaged and cannot be reused.
The objective is to measure the maximum force before failure.
Proof-Load Test
A defined load is applied without intentionally breaking the sample.
The objective is to confirm that the product can withstand the required force without unacceptable damage or permanent deformation.
A proof-load value should not be treated as a breaking-force result, and a breaking-force result should not automatically be used as a safe working load.
Equipment Required
A typical breaking-force test requires:
Landtek FM-207-500K display unit
External force sensor
Suitable high-capacity test stand
Pulling or compression mechanism
Sample-specific grips
Load-rated connectors
Secure mounting structure
Protective guard
Test-recording method
The force gauge measures force but does not generate the load. A separate manual, motorised, hydraulic or customised loading mechanism is required.
Step 1: Define the Test Method
Before testing, determine:
Product being tested
Expected breaking-force range
Pull or compression direction
Required measurement unit
Sample preparation method
Grip or fixture type
Loading speed
Number of samples
Applicable internal or external standard
Information to be recorded
Tests should use the same procedure if the results will be compared.
Changing the fixture, loading speed or sample position may change the measured breaking force.
Step 2: Confirm the Correct Gauge Range
The FM-207-500K measures up to 500 kgf.
It may be suitable when the expected breaking force is within this range and not too small for useful measurement.
Choose a lower-capacity force gauge if the expected breaking force is very low. Select a higher-capacity system if the sample may exceed 500 kgf.
Avoid selecting a gauge only because its range is larger. The expected test force should match the useful range of the instrument.
Step 3: Select the Correct Grip or Fixture
The grip must hold the sample securely without creating an unintended weak point.
Examples include:
Wedge grips
Cable clamps
Capstan grips
Hooks
Clevis connections
Threaded adapters
Compression plates
Vise-type grips
Custom-machined fixtures
If the sample slips from the grip before breaking, the recorded value may represent grip performance rather than the sample’s actual breaking strength.
If the grip damages the sample prematurely, the result may also be misleading.
Step 4: Inspect the Complete Test System
Check the condition and capacity of:
Test frame
Sensor
Hooks
Bolts
Shackles
Clamps
Mounting plates
Grip surfaces
Protective guard
Every load-bearing part should safely withstand the expected force.
The test system’s overall capacity is limited by its weakest component.
Step 5: Align the Sensor and Sample
The applied force should pass through the sensor in a straight line.
Avoid:
Side loading
Bending
Twisting
Off-centre pulling
Uneven compression
Sudden impact
Poor alignment can cause unstable readings, incorrect failure behaviour or sensor damage.
Step 6: Zero the Force Gauge
Install the sensor, fixture and sample before zeroing the gauge.
Remove any unintended load and confirm that the display remains stable at zero.
If the reading drifts, inspect the system for:
Residual tension
Binding fixtures
Unstable mounting
Environmental vibration
Loose sensor connection
Do not start the breaking test until the zero reading is stable.
Step 7: Select Peak-Value Mode
Peak-value mode is normally used for a breaking-force test.
As the load increases, the instrument records the highest force reached. When the sample fails and the applied force drops, the maximum value remains available on the display.
Real-time mode may also be used while preparing or checking the setup, but peak mode is the key function for capturing the failure force.
Step 8: Apply the Force Gradually
Increase the load at a controlled rate.
Avoid sudden jerking or impact because this may:
Produce an artificially high peak
Damage the sensor
Cause unpredictable sample failure
Reduce test repeatability
Create a safety hazard
Observe the sample and fixture throughout the test, but remain outside the direct failure path.
Stop immediately if:
The overload warning activates
The fixture slips
The test frame bends
The sensor becomes misaligned
A connection point becomes unstable
The expected force exceeds the selected range
Step 9: Record the Peak Force
After the sample fails, record the displayed peak force.
A proper test record should include:
Sample identification
Product description
Material
Sample dimensions
Batch or supplier
Measurement unit
Peak breaking force
Loading method
Loading speed
Fixture used
Failure location
Failure description
Test date and operator
The FM-207-500K can store up to 99 measurement records, but product and failure information should also be documented separately.
Step 10: Examine the Failure Mode
The force value alone does not explain why the product failed.
For example:
A cable breaking in its centre may indicate material failure
A cable pulling out of a terminal may indicate a crimping problem
A hook bending may indicate inadequate stiffness
A bolt pulling out with surrounding material may indicate base-material failure
A sample slipping from the grip may indicate an invalid test
A bonded joint separating cleanly may indicate poor adhesion
Photographing the sample after the test can make the report more useful.
How Many Samples Should Be Tested?
Testing only one sample provides limited information.
Where practical, test multiple samples prepared under the same conditions. This helps identify:
Average breaking force
Lowest result
Highest result
Variation between samples
Unusual failure modes
Production inconsistency
The number of required samples should follow the applicable standard, customer requirement or internal quality procedure.
Common Breaking-Test Mistakes
Using the Wrong Measurement Range
A gauge with insufficient capacity may be overloaded, while a gauge with excessive capacity may provide less useful resolution for small forces.
Allowing the Sample to Slip
A slipping sample may not produce its actual breaking-force result.
Changing the Loading Speed
Different loading speeds may produce different results, especially for plastic, rubber, adhesives and other time-dependent materials.
Applying Force at an Angle
Misalignment can introduce bending and cause premature failure.
Recording Only the Maximum Number
The failure mode, sample details and test conditions are also essential.
Treating Breaking Force as Safe Working Load
A measured breaking force is not automatically the safe load of the product. Appropriate safety factors and applicable standards must be considered.
Safety During Destructive Testing
When a sample breaks, stored energy may be released suddenly.
Recommended precautions include:
Install a suitable protective guard
Keep personnel away from the loading line
Inspect fixtures before each test
Use load-rated connections
Wear appropriate personal protective equipment
Do not touch the sample while it is under load
Apply force gradually
Stop if any part of the setup becomes unstable
Follow the relevant workplace safety procedure
High-force destructive testing should only be conducted by trained personnel.
Frequently Asked Questions
Can the FM-207-500K automatically break the sample?
No. It measures force but does not generate it. A test stand or loading mechanism is required.
Can it record the highest force before failure?
Yes. Peak-value mode captures and retains the maximum measured force.
Can it test in both pulling and compression directions?
Yes. The external sensor can measure tension and compression when installed correctly.
What happens if the sample requires more than 500 kgf to break?
The FM-207-500K is not suitable for a test expected to exceed its range. A higher-capacity system is required.
Can the test result be used for product certification?
That depends on the applicable standard, calibration requirements, equipment specification and accreditation scope. The force gauge alone does not automatically provide certified product approval.
Does the test stand come with the gauge?
A suitable stand and fixture are normally selected according to the required force and sample design. Confirm the supplied configuration before ordering.
Plan Your Breaking-Force Test in Malaysia
Before selecting the equipment, send MTM Precision:
Photo and dimensions of the sample
Expected breaking force
Pull or compression test
Required test travel
Proposed grip or fixture
Number of samples
Applicable test standard
Required loading method
Calibration and reporting requirements
MTM Precision can help determine whether the Landtek FM-207-500K is suitable for the intended breaking-force application.
Contact MTM Precision
MTM Precision Sdn. Bhd. (744811-A)
Telephone: +603-8080 7172
WhatsApp: +6019-665 7346 / +6016-660 7346
Email: mtmpre@yahoo.com / enquiry@mtmpre.com.my
Website: www.mtmpre.com.my
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar Lapan Belas,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Supply and technical support are available throughout Malaysia, including Selangor, Kuala Lumpur, Johor, Penang, Perak, Melaka, Negeri Sembilan, Pahang, Kedah, Perlis, Terengganu, Kelantan, Sarawak and Sabah.
16 Sep 2026