Peak Hold vs Real-Time Measurement on a Digital Force Gauge Malaysia
Peak Hold vs Real-Time Measurement on a Digital Force Gauge Malaysia
Digital force gauges commonly provide real-time measurement and peak-hold measurement, but these two modes serve different purposes.
Real-time mode shows the force currently being applied. Peak-hold mode captures the highest force reached during the test.
Selecting the correct mode is important when testing cables, fasteners, hooks, springs, connectors and mechanical components.
The Landtek FM-207-500K Digital Force Gauge supports both modes and measures push or pull force up to ±500 kgf, ±4900 N or ±1100 lbf.
What Is Real-Time Force Measurement?
In real-time mode, the displayed reading continuously changes according to the force being applied to the sensor.
For example:
When the applied force increases, the reading increases
When the force decreases, the reading decreases
When the load is completely removed, the reading should return close to zero
This mode allows the operator to observe the force throughout the test.
When Should Real-Time Mode Be Used?
Real-time measurement is suitable when the operator needs to reach, maintain or monitor a specific force.
Typical applications include:
Applying a specified proof load
Holding a component at a target force
Monitoring spring compression
Adjusting cable tension
Checking pressing force
Observing force changes during assembly
Monitoring gradual deformation
Confirming the force applied by a mechanism
For example, if a component must withstand 200 kgf for 30 seconds, the operator can use real-time mode to increase the load to 200 kgf and monitor it during the holding period.
Advantages of Real-Time Measurement
Real-time mode helps the operator:
See the current force
Control the load as it increases
Maintain a specified test force
Observe fluctuations
Detect slipping or gradual movement
Adjust machinery or fixtures
However, real-time mode may not be suitable when the maximum force appears only briefly and then disappears.
What Is Peak-Hold Measurement?
Peak-hold mode records and retains the highest force measured during a test.
For example, if the force rises from 0 kgf to 300 kgf and then drops suddenly when the sample breaks, the display retains the maximum value of approximately 300 kgf.
This allows the operator to read the result after the event has occurred.
When Should Peak Mode Be Used?
Peak measurement is suitable when the main objective is to determine the maximum force.
Typical applications include:
Breaking-force testing
Cable pull-out testing
Terminal separation testing
Connector release-force testing
Maximum compression testing
Hook deformation testing
Fastener extraction testing
Destructive testing
Measuring the force required to open a latch
Comparing maximum force between samples
Peak mode is especially useful when failure occurs too quickly for the operator to observe the maximum real-time reading.
Advantages of Peak-Hold Measurement
Peak mode helps the operator:
Capture a short-duration maximum force
Record the force immediately before failure
Compare maximum values between samples
Avoid relying on visual observation
Perform pull-out and breaking tests more efficiently
The peak reading must normally be cleared before starting the next measurement.
If the previous peak is not reset, the operator may accidentally record an old value.
Real-Time vs Peak Hold: What Is the Difference?
Measurement modeWhat the display showsBest used forReal-timeForce currently appliedProof load, monitoring, adjustment and holding testsPeak holdHighest force reachedBreaking, pull-out, release and maximum-force tests
The correct choice depends on the test objective, not only on the product being tested.
The same component may require both modes during different stages of testing.
Example 1: Cable Proof-Load Test
A cable assembly must withstand 150 kgf without slipping.
Use real-time mode to:
Increase the pulling force gradually
Stop at approximately 150 kgf
Maintain the required force for the specified time
Observe whether the cable slips or becomes damaged
Reduce the load safely
The purpose is not to break the cable. It is to verify that the cable survives the specified test load.
Example 2: Cable Breaking-Force Test
The objective is to determine how much pulling force the cable can withstand before breaking.
Use peak mode to:
Zero the force gauge
Increase the pulling force gradually
Continue until the cable breaks or separates
Read the retained maximum force
Record the failure location and failure type
The result is the measured peak force before failure.
Example 3: Spring Compression Test
If the objective is to determine the force produced when a spring reaches a specified compression distance, use real-time mode.
The operator compresses the spring to the required position and records the current force.
If the objective is to determine the maximum compression force reached during the entire cycle, peak mode may be more suitable.
Example 4: Fastener Pull-Out Test
When a fastener is pulled from a sample, the force may increase steadily and drop immediately after the fastener releases.
Use peak mode to capture the maximum extraction force.
The report should also state whether:
The fastener itself broke
The fastener pulled out
The surrounding material failed
The grip slipped
The fixture moved
The same peak number can represent very different failure conditions.
Example 5: Applying a Controlled Assembly Force
A production process may require a component to be assembled with a force between 80 kgf and 100 kgf.
Use real-time mode so the operator can watch the force during assembly and stop within the specified range.
Peak mode alone would show the highest force but would not provide the same level of control while the force is being applied.
Using Both Modes in One Test
Some test procedures may use both real-time and peak measurement.
For example:
Use real-time mode to check that the fixture is stable
Apply a small preload
Confirm correct sensor alignment
Switch to peak mode
Continue until the sample fails
Record the maximum force
The procedure should clearly state when each mode is used to ensure that different operators follow the same method.
What Can Cause an Incorrect Peak Reading?
Peak mode may capture an unintended force if the test setup is not controlled.
Possible causes include:
Sudden impact
Jerking the sample
Fixture slippage
A connector striking the sensor
Excessive loading speed
Side loading
Mechanical vibration
Previous peak reading not cleared
The load should be applied smoothly, and the setup should be inspected before accepting the result.
What Can Cause an Unstable Real-Time Reading?
Real-time readings may fluctuate because of:
Hand movement
Machine vibration
Sample slippage
Misaligned fixtures
Irregular loading speed
Loose mounting
Sensor cable movement
An unstable test stand
A secure mechanical fixture usually provides better repeatability than manually holding the sensor during high-force testing.
Why Loading Speed Matters
The measured force may change when the loading speed changes.
This can be especially important for:
Rubber
Plastic
Adhesives
Textiles
Flexible cables
Soft packaging
Viscoelastic materials
If results will be compared between samples, use a consistent loading speed and test method.
Peak mode records the highest force, but it does not automatically control the test speed.
Using Peak Mode Safely
Peak mode may encourage an operator to continue loading until the sample fails. Appropriate safety controls are therefore essential.
Recommended precautions include:
Use a protective guard
Keep personnel away from the direct loading path
Confirm all fixture capacities
Apply force gradually
Avoid standing behind the sample
Stop if the fixture becomes unstable
Do not exceed the instrument’s measuring range
Wear appropriate personal protective equipment
A retained peak value does not justify overloading the gauge.
FM-207-500K Measurement Functions
The Landtek FM-207-500K provides:
Real-time force measurement
Peak-value measurement
kgf, N and lbf units
Up to 99 stored readings
External force sensor
USB or optional Bluetooth data output
Overload warning
Dual-direction digital display
Its high-capacity external sensor makes it suitable for properly engineered push-and-pull testing arrangements.
Frequently Asked Questions
Which mode should I use for a pull-out test?
Use peak mode when the objective is to capture the maximum force before the component pulls out.
Which mode should I use for a proof-load test?
Use real-time mode to reach and maintain the specified force.
Does peak mode show the force after the sample breaks?
It retains the highest force measured before or during the failure event, even after the applied force drops.
Must I reset the peak before each test?
Yes. Clear the previous peak result before beginning a new measurement.
Can real-time mode record the maximum force?
It shows the current force. If the highest value occurs very quickly, the operator may not be able to observe it accurately. Peak mode is better for capturing a brief maximum.
Can the FM-207-500K control the loading speed?
No. It measures force. The test stand or loading mechanism controls movement and loading speed.
Select the Correct Force Gauge and Test Method in Malaysia
Before choosing a force-testing system, provide MTM Precision with:
Product being tested
Expected minimum and maximum force
Proof, breaking or pull-out test
Required measurement unit
Sample dimensions
Proposed fixture
Loading method
Applicable standard
Calibration and reporting requirements
MTM Precision can help evaluate whether the Landtek FM-207-500K and its real-time or peak measurement functions are suitable for the application.
Contact MTM Precision
MTM Precision Sdn. Bhd. (744811-A)
Telephone: +603-8080 7172
WhatsApp: +6019-665 7346 / +6016-660 7346
Email: mtmpre@yahoo.com / enquiry@mtmpre.com.my
Website: www.mtmpre.com.my
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar Lapan Belas,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Supply and technical support are available throughout Malaysia, including Selangor, Kuala Lumpur, Johor, Penang, Perak, Melaka, Negeri Sembilan, Pahang, Kedah, Perlis, Terengganu, Kelantan, Sarawak and Sabah.
16 Sep 2026