How to Check Hot Aisle and Cold Aisle Airflow in a Data Centre Malaysia
How to Check Hot Aisle and Cold Aisle Airflow in a Data Centre Malaysia
Data centre cooling is not only about producing cold air.
The cold air must also reach the IT equipment effectively, while heated exhaust air needs to return through the intended path.
Poor airflow distribution can contribute to hot spots even when the cooling system itself is operating.
A portable digital anemometer such as the TASI TA642C High Accuracy Digital Anemometer can support airflow investigation around selected data centre cooling points.
It can be useful for spot measurements, troubleshooting and before-and-after comparisons.
Why Airflow Matters in a Data Centre
Servers and other IT equipment generate heat continuously.
Cooling systems remove this heat, but effective operation depends on air distribution.
A simplified airflow path may look like:
Cooling Supply → Cold Aisle → IT Equipment → Hot Aisle → Cooling Return
Problems can occur when air does not follow the intended path.
Examples include:
Insufficient supply airflow
Uneven airflow distribution
Air bypass
Hot and cold air mixing
Obstructed perforated tiles
Changes in rack arrangement
Portable airflow measurement can help technicians investigate these conditions.
What Is a Cold Aisle?
A cold aisle is arranged so that the fronts of server racks receive cooler supply air.
IT equipment draws this air through the rack.
The objective is to deliver appropriate cooling air to the equipment intake.
If airflow distribution is poor, some racks may receive different cooling conditions from others.
What Is a Hot Aisle?
The hot aisle receives heated air discharged from the rear of the IT equipment.
This warmer air should be directed back toward the cooling system according to the data centre design.
Good separation between supply and return air helps reduce unnecessary mixing.
Where Can You Use an Anemometer?
Depending on the data centre cooling design, portable airflow measurements may be taken around suitable points such as:
Perforated floor tiles
Cooling supply outlets
Selected rack intake areas
Return air locations
Other accessible air distribution points
The objective should be defined before taking measurements.
Do not randomly measure different locations and assume the readings are directly comparable.
Checking Perforated Floor Tile Airflow
Raised-floor data centres may use perforated tiles to supply cooling air into the cold aisle.
A technician can use an anemometer to investigate whether air is moving through selected tiles.
If several similar tiles are compared, large differences may indicate that further investigation is needed.
However, one velocity reading at the centre of a tile does not automatically represent the total airflow through that tile.
Why Multiple Measurements Matter
Airflow across a perforated tile or grille can be uneven.
For example:
Centre: Higher velocity
Corner: Lower velocity
Near obstruction: Different again
Where more representative airflow information is required, multiple measurement points may be necessary.
The appropriate procedure depends on the objective and required measurement quality.
Air Velocity vs CFM
Air velocity tells you how fast air is moving at a point.
CFM tells you the volume of air moving through a defined area.
The basic relationship is:
Airflow = Air Velocity × Area
The TA642C supports airflow measurements including:
CFM
CMM
CMS
Correct area information and measurement technique are important when determining airflow volume.
Compare Similar Cooling Points
One useful troubleshooting approach is comparison.
Suppose a cold aisle contains six similar perforated tiles.
Five produce relatively similar measurements.
One is substantially different.
This does not automatically identify the problem, but it provides a reason to investigate that location.
Possible factors may include:
Underfloor obstruction
Damper setting
Tile configuration
Air distribution
Other cooling-system conditions
Checking Rack Intake Areas
Portable air velocity measurements may also be useful around selected rack intake locations.
For example, technicians can compare:
Lower rack area
Middle rack area
Upper rack area
If conditions vary substantially, this information can be considered together with temperature measurements and the cooling-system design.
An anemometer alone does not determine whether server inlet conditions meet the required data centre specification.
Airflow and Temperature Should Be Used Together
Airflow information becomes more useful when interpreted with temperature.
For example:
Low airflow + elevated temperature
may suggest a different troubleshooting direction from:
Strong airflow + elevated temperature
The complete cooling investigation may require several parameters.
The TA642C can support portable airflow and temperature checks, but larger data centres commonly use permanent environmental monitoring systems as well.
Look for Airflow Obstructions
Air distribution can change when physical conditions change.
Check for factors such as:
Cables
Equipment
Temporary materials
Blocked tiles
Rack changes
Floor modifications
Other obstructions
A cooling configuration that worked previously may behave differently after equipment or layout changes.
Check After Rack Installation
Installing new racks or IT equipment can alter cooling requirements and airflow distribution.
After significant changes, technicians may perform spot checks around selected cooling points.
The objective is to identify whether the new arrangement has changed airflow patterns that deserve further investigation.
Check Before and After Cooling Adjustments
Suppose facility personnel adjust:
Fan settings
Dampers
Perforated tile positions
Cooling configuration
Airflow measurements can be recorded before the adjustment.
After the change, repeat the measurements at the same locations under comparable conditions.
This provides more objective information about what changed.
Build a Data Centre Airflow Baseline
Instead of waiting for a hot spot complaint, facility teams can establish selected baseline measurement points.
For example:
Cold Aisle A – Tile 01
Cold Aisle A – Tile 02
Rack A05 – Intake Lower
Rack A05 – Intake Upper
Future measurements can be compared with these baseline conditions.
A significant change may justify further investigation.
Why Data Logging Can Help
A data centre may contain many measurement points.
The TA642C provides data storage functions that can support technicians collecting multiple measurements.
USB/PC connectivity can also be useful when measurement data needs to be reviewed or organised later.
This is useful for portable inspection work where measurements are collected across several cooling locations.
Airflow Problems May Not Be Cooling-Unit Problems
A hot spot does not automatically mean that the cooling unit has failed.
Possible causes can involve:
Air distribution
Rack arrangement
Obstruction
Hot/cold air mixing
Cooling control
Equipment heat load
Other system conditions
Portable measurements help technicians gather information before deciding where to investigate next.
Can TA642C Replace Data Centre Monitoring?
No.
A portable anemometer and a permanent monitoring system serve different purposes.
The TA642C can be useful for:
Spot checking
Troubleshooting
Comparing airflow locations
Before-and-after measurements
Maintenance inspection
Permanent monitoring systems are more suitable when continuous environmental data and alarms are required.
Other Measurements May Also Be Required
A complete data centre environmental assessment may involve measurements such as:
Temperature
Relative humidity
Differential pressure
Electrical parameters
Power consumption
Other facility parameters
Air velocity is one part of the overall picture.
TASI TA642C for Data Centre Airflow Measurement Malaysia
The TASI TA642C High Accuracy Digital Anemometer can support data centre facility and maintenance teams that need portable air velocity and airflow measurements around selected cooling points.
Its separate probe design can be useful when positioning the sensor around perforated tiles, cooling outlets and other accessible airflow locations.
The data storage and USB/PC functions can also support measurement records when multiple points need to be checked.
For product availability and technical enquiries:
MTM Precision Sdn Bhd
Showroom & Service Centre: Puchong, Selangor, Malaysia
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Contact MTM Precision for more information about the TASI TA642C Digital Anemometer for data centre airflow, cooling inspection and HVAC measurement applications in Malaysia.
26 Sep 2026