How to Check Factory Ventilation Airflow During Preventive Maintenance Malaysia
How to Check Factory Ventilation Airflow During Preventive Maintenance Malaysia
Factory ventilation systems may operate every day without receiving much attention until workers complain about heat, poor air movement or uncomfortable working conditions.
A fan that is running does not necessarily mean the ventilation system is delivering the same airflow as before.
For preventive maintenance, technicians can periodically measure air velocity and airflow at selected ventilation points and compare the results over time.
The TASI TA642C High Accuracy Digital Anemometer can support this type of portable airflow measurement in factories and industrial facilities in Malaysia.
Why Include Airflow in Preventive Maintenance?
Many maintenance programmes already check:
Motors
Pumps
Compressors
Electrical systems
HVAC equipment
Filters
Fans
Ventilation airflow can also be monitored.
The purpose is not necessarily to perform a complete ventilation certification during every maintenance round.
Instead, technicians can establish repeatable measurement points and identify significant changes.
Start with a Baseline
A baseline is a measurement taken when the ventilation system is known to be operating under normal conditions.
For example:
Exhaust Fan EF-01 – Measurement Point A
Fresh Air Fan FAF-02 – Main Duct
Production Area – Supply Vent 03
Record the measurement together with the operating condition.
Future readings can then be compared with this baseline.
What Should You Measure?
Depending on the system, technicians may measure:
Air velocity
Airflow volume
Air temperature
Airflow volume may be expressed in units such as:
CFM
CMM
CMS
The appropriate measurement depends on the maintenance objective and system design.
Air Velocity vs Airflow
Air velocity describes how fast air is moving.
Airflow describes how much air volume is moving through a defined area.
The basic relationship is:
Airflow = Air Velocity × Area
For quick comparison at the same measurement point, air velocity may already provide useful information.
When airflow volume is required, the measurement area must also be considered.
Where Can Factory Maintenance Teams Measure?
Potential measurement points include:
General ventilation fans
Exhaust ducts
Fresh-air ducts
AHU supply ducts
Air-conditioning outlets
Equipment room ventilation
Warehouse ventilation
Workshop ventilation
Production-area ventilation
Choose locations that can be accessed safely and measured repeatedly.
Keep Measurement Points Consistent
Consistency is important for preventive maintenance.
If January's measurement is taken at one point and April's measurement is taken somewhere completely different, the readings may not be directly comparable.
Document the measurement location clearly.
For example:
Factory Block A – Exhaust Fan EF-03 – Outlet Point A
This allows another technician to repeat the measurement later.
Keep Operating Conditions Consistent
Before comparing measurements, consider whether the system was operating under similar conditions.
Check factors such as:
Fan speed
Damper position
HVAC operating mode
Production condition
Measurement point
Probe orientation
A change in operating condition may explain a change in airflow.
Why Can Factory Airflow Reduce Over Time?
Several factors can affect ventilation performance.
Dirty Filters
Filters can accumulate contamination and increase resistance.
Blocked Grilles
Dust and debris may restrict openings.
Fan Condition
Fan or motor performance may change.
Damper Position
A damper may have been adjusted or partially closed.
Duct Restriction
Obstruction or damage may affect airflow.
System Modification
Changes to machinery, partitions or ventilation layouts can alter air distribution.
Airflow measurement helps identify that something has changed, but further inspection is usually required to determine the cause.
Example: Monthly Exhaust Fan Check
A factory maintenance team selects several important exhaust fans.
Every month, technicians measure the same points.
For several months, the results remain reasonably consistent.
Later, one exhaust system shows a substantial reduction.
Instead of waiting until the ventilation becomes obviously poor, the maintenance team can inspect that system earlier.
This is the basic principle of condition-based maintenance:
Measure → Compare → Investigate
Before-and-After Filter Replacement
Airflow measurement can also document maintenance results.
Before Replacement
Measure selected airflow points.
Replace the Filter
Perform the required maintenance.
After Replacement
Repeat the measurements under comparable conditions.
If airflow changes significantly, the technician now has measurable before-and-after information.
Before-and-After Fan Servicing
The same method can be applied when servicing ventilation fans.
Record measurements before maintenance.
After the fan is serviced, repeat the test.
This provides more useful documentation than simply recording:
“Fan serviced.”
Using TASI TA642C for Multiple Measurement Points
Factories may have many ventilation measurement locations.
The TA642C provides data storage functions that can support technicians collecting multiple measurements.
USB/PC connectivity can also help when recorded data needs to be reviewed or organised later.
This can be useful for preventive maintenance programmes involving repeated inspections.
Factory HVAC Preventive Maintenance
The same approach can be applied to factory HVAC systems.
Potential checks include:
AHU airflow
FCU airflow
Supply air
Return air
Fresh air
Exhaust air
If workers complain that one area is warmer or has weaker air movement, measurements can help compare that area with normal zones.
Equipment Room Ventilation
Electrical rooms, compressor rooms, pump rooms and other equipment spaces may use ventilation to manage heat.
Airflow measurements can help maintenance teams check whether ventilation is still operating consistently.
However, temperature, equipment heat load and system design should also be considered.
An anemometer alone cannot determine whether an equipment room cooling system is adequate.
Warehouse Ventilation
Large warehouses can have very different airflow conditions in different areas.
Portable measurements may help investigate:
Weak air movement
Exhaust performance
Supply ventilation
Changes after building modifications
For large spaces, measurement planning becomes particularly important because one reading cannot represent the entire building.
Ventilation and Workplace Safety
There is an important limitation.
Measuring airflow does not automatically prove that a workplace is safe.
An anemometer does not directly measure:
Oxygen
Carbon monoxide
Hydrogen sulphide
Combustible gases
VOC concentration
Dust exposure
Other hazardous substances
Where occupational exposure or hazardous atmospheres are involved, appropriate instruments, procedures and professional assessment are required.
Create a Simple Ventilation Maintenance Record
A useful record may contain:
Equipment ID
Measurement Location
Date
Fan Operating Condition
Air Velocity
Airflow
Temperature
Maintenance Performed
Remarks
Over time, these records can help technicians recognise changes more easily.
Don't Wait for Complete Failure
Preventive maintenance is not only about repairing equipment after it stops.
A ventilation fan may continue rotating even when the overall airflow condition has changed.
Periodic measurement gives maintenance teams another way to observe system condition before a major complaint or failure occurs.
TASI TA642C for Factory Preventive Maintenance Malaysia
The TASI TA642C High Accuracy Digital Anemometer can support factory maintenance teams that need portable air velocity, airflow and temperature measurements for ventilation and HVAC inspections.
Typical applications include:
Factory exhaust
Fresh-air ventilation
AHU and FCU systems
Equipment room ventilation
Workshop ventilation
Warehouse ventilation
General preventive maintenance
The instrument provides measurement information to support troubleshooting and maintenance decisions, while the actual ventilation requirement should still be evaluated according to the system design and applicable procedures.
For product availability and technical enquiries:
MTM Precision Sdn Bhd
Showroom & Service Centre: Puchong, Selangor, Malaysia
Tel: 03-8080 7172
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Website: www.mtmpre.com.my
Contact MTM Precision for more information about the TASI TA642C Digital Anemometer for factory ventilation, HVAC airflow and preventive maintenance applications in Malaysia.