How to Perform Anchor Pull-Out Test Using Langry APT200 Malaysia
How to Perform Anchor Pull-Out Test Using Langry APT200 Malaysia
Anchor Pull-Out Testing Procedure with Langry APT200
The Langry APT200 Anchor Pull-Out Tester is a professional hydraulic testing instrument designed to apply controlled tensile loads to installed anchors, anchor rods, steel bars, expansion bolts and other suitable anchoring components.
With a maximum measurement range of 200kN, the APT200 is commonly referred to as a 20-ton class anchor pull-out tester and is suitable for construction inspection, civil engineering, façade works and QA/QC applications in Malaysia.
This guide provides a general overview of how an anchor pull-out test may be performed using the Langry APT200.
The exact test procedure, proof load, acceptance criteria, loading rate and test duration should always follow the relevant project specification, approved test method and engineer's requirements.
What Is an Anchor Pull-Out Test?
An anchor pull-out test applies a controlled tensile force to an installed anchor.
The purpose is to evaluate how the installed anchoring system behaves when subjected to the specified tensile load.
Depending on the project, testing may be performed as a:
Proof test
Quality control test
Installation verification test
Site investigation
Comparative test
Ultimate load test
It is important to establish the purpose of the test before starting because the required loading procedure and acceptance criteria can be different.
Equipment Required for Anchor Pull-Out Testing
A typical test setup may include:
Langry APT200 Anchor Pull-Out Tester
Hydraulic cylinder
Digital force indicator
Hydraulic pump
Pull rod
Suitable adapter or converter
Appropriate support or reaction arrangement
Anchor under test
Project test documentation
Appropriate personal protective equipment
The exact accessories required depend on the anchor type, diameter, geometry and test arrangement.
Langry APT200 Basic Specifications
SpecificationLangry APT200Measurement Range0–200kNCapacity ClassApprox. 20 TonCylinder Center Hole35mmCylinder Stroke70mmCylinder WeightApprox. 13kgCommon AnchorageΦ6–Φ25Pull RodM24ConverterM6–M22Data Storage500 RecordsContinuous Working Time>200 HoursAccuracy ClassificationEN ISO 7500-1 Class 1
Step 1 – Identify the Anchor to Be Tested
Before setting up the equipment, identify the anchor and record the relevant information.
This may include:
Anchor type
Anchor manufacturer
Anchor diameter
Anchor length
Embedment depth
Base material
Installation location
Installation date
Required test load
Project reference
The operator should also confirm whether the test is intended to verify a specified proof load or determine another performance characteristic.
Step 2 – Inspect the Test Area
Inspect the anchor and surrounding substrate before installing the pull-out tester.
Look for obvious conditions such as:
Cracked concrete
Damaged anchor
Loose fixing
Irregular surface
Insufficient exposed thread or rod
Obstructions around the anchor
Edge proximity
Existing substrate damage
Any unusual condition should be recorded before testing.
This is important because the condition of the surrounding material can influence the test setup and interpretation of results.
Step 3 – Select the Correct Adapter
The connection between the pull-out tester and the anchor must be suitable for the anchor being tested.
The Langry APT200 uses an M24 pull rod with converters covering suitable configurations from M6 to M22.
Select an appropriate adapter according to the anchor size and test arrangement.
The connection should be secure and properly aligned before applying load.
Step 4 – Position the Hydraulic Cylinder
Place the hydraulic cylinder over the anchor and arrange the pulling system according to the required test configuration.
Correct positioning is important.
The pulling force should be applied as concentrically as practical to avoid introducing unnecessary side loading or bending.
The reaction surface should also be suitable for the test.
An incorrect reaction arrangement may affect the measured result or damage the surrounding substrate.
Step 5 – Connect the Pulling Assembly
Connect the pull rod, adapter and anchor securely.
Before applying significant pressure, check that:
Connections are properly engaged
Pull rod is correctly positioned
Hydraulic cylinder is stable
Reaction arrangement is stable
Test equipment is aligned
Hydraulic components are correctly connected
Personnel are clear of the potential failure path
Never begin a high-load pull test with a loose or poorly aligned setup.
Step 6 – Zero the Digital Indicator
Before starting the measurement, switch on the digital force indicator and confirm that the reading is correctly zeroed according to the equipment operating procedure.
This provides a clear starting reference before the tensile load is applied.
Step 7 – Apply the Load Gradually
Operate the hydraulic pump to increase the tensile load.
The load should be applied according to the approved testing procedure.
Avoid uncontrolled or sudden loading.
Depending on the project specification, the test may require:
Progressive loading
Specific loading stages
A defined proof load
Holding the load for a specified period
Recording readings at different load levels
Do not assume that every anchor should be tested to the maximum 200kN capacity of the APT200.
The required test load is determined by the anchor system and project requirements—not by the maximum capacity of the tester.
Step 8 – Monitor the Applied Force
Observe the digital display as the load increases.
The operator should monitor the test continuously and look for abnormal behaviour.
Depending on the test objective, observations may include:
Applied tensile load
Anchor movement
Substrate cracking
Anchor slipping
Sudden reduction in load
Visible deformation
Failure of the fixing
Condition after holding the specified load
If abnormal or unsafe behaviour occurs, loading should be stopped in accordance with the approved test procedure.
Step 9 – Hold the Required Test Load
Some anchor testing procedures require the specified load to be maintained for a defined period.
The required holding time depends on the project specification or approved test method.
During this period, the operator should monitor the load and anchor behaviour.
A stable reading alone does not automatically mean that an anchor has passed.
The result must be assessed against the applicable acceptance criteria.
Step 10 – Release the Hydraulic Load
After completing the required loading sequence, release the hydraulic pressure in a controlled manner.
Do not release the system abruptly.
Once the load has returned to a safe level, the pulling assembly and hydraulic cylinder can be removed.
Step 11 – Inspect the Anchor After Testing
Inspect the anchor and surrounding substrate again after the test.
Look for:
Permanent movement
Anchor deformation
Concrete cracking
Pull-out
Surface damage
Thread damage
Other visible changes
Post-test observations can provide useful information when preparing the test report.
Step 12 – Record the Test Result
The Langry APT series supports storage of up to 500 measurement records.
However, a complete project record may require more information than the force reading alone.
A typical anchor pull-out test record may include:
Project name
Test location
Anchor identification
Anchor type
Anchor diameter
Base material
Test date
Test equipment
Required test load
Maximum applied load
Holding time
Observations
Pass/fail result according to specified criteria
Operator information
Good documentation is particularly important when multiple anchors are tested across a construction project.
What Does a Failed Anchor Pull-Out Test Mean?
A failed result does not always have one single cause.
Possible factors may include:
Incorrect Installation
Improper installation can reduce the performance of the anchor.
Incorrect Hole Diameter
A drilled hole that does not meet the anchor manufacturer's requirements may affect anchorage.
Insufficient Embedment
An anchor installed with inadequate embedment may not achieve the required performance.
Poor Hole Cleaning
For some anchoring systems, particularly bonded anchors, hole preparation and cleaning are critical.
Weak or Damaged Base Material
The condition and strength of the substrate can influence anchor performance.
Incorrect Anchor Selection
The selected anchor may not be appropriate for the application, substrate or required load.
Installation Workmanship
Even a correctly specified anchor can perform poorly if installation procedures are not followed.
The cause of a failed test should therefore be investigated rather than assuming that the anchor product itself is defective.
Proof Testing vs Pulling an Anchor to Failure
These two approaches should not be confused.
Proof Testing
A proof test normally applies a predetermined load to verify the installed anchor against specified project requirements without intentionally loading it to destruction.
Ultimate or Failure Testing
A test intended to investigate ultimate performance continues according to a defined procedure until a failure criterion is reached.
The appropriate method depends on the engineering objective.
For actual construction projects, always follow the engineer's approved testing procedure and acceptance criteria.
Important Safety Considerations
Anchor pull-out testing can involve substantial forces.
A 200kN tester is capable of generating very high tensile loads.
Operators should therefore:
Use appropriate PPE
Inspect equipment before testing
Use suitable adapters
Confirm secure connections
Maintain proper alignment
Keep unnecessary personnel away
Avoid standing in the potential failure path
Never exceed equipment limits
Follow the manufacturer's operating instructions
Follow the project's approved testing procedure
Anchor, adapter or test fixture failure under high load can create a serious hazard.
Common Mistakes During Anchor Pull-Out Testing
Some common testing mistakes include:
Using the wrong adapter
Poor alignment of the tester
Applying load too quickly
Testing without a defined test load
Using an unsuitable reaction arrangement
Ignoring substrate condition
Failing to record the anchor location
Confusing proof testing with destructive testing
Assuming tester capacity equals required test load
Testing without clear acceptance criteria
A professional pull-out test requires both suitable equipment and a properly defined testing procedure.
Why Use the Langry APT200?
The Langry APT200 provides a useful combination of capacity and portability for professional anchor testing.
Its 200kN / approximately 20-ton capacity makes it suitable for a broad range of construction and engineering applications where a lower-capacity pull tester may not provide sufficient range.
Typical users include:
Construction contractors
Civil engineering companies
Façade contractors
Anchor installation companies
QA/QC teams
Engineering consultants
Inspection companies
Testing laboratories
Infrastructure contractors
Frequently Asked Questions
How much force can the Langry APT200 apply?
The APT200 has a measurement range of 0–200kN, approximately equivalent to a 20-ton class system.
Can I simply test every anchor to 200kN?
No. The 200kN figure is the capacity of the tester. The actual test load must follow the anchor specification, approved test method and project engineering requirements.
Can the APT200 test expansion bolts?
Yes, suitable expansion bolts are among the applications of this type of anchor pull-out tester, provided the correct testing setup and accessories are used.
Can it test steel bars?
The Langry APT series is designed for pull-out testing applications involving suitable anchor rods, steel bars and other anchoring components.
Can the APT200 be used for curtain wall projects?
Yes. Anchor pull-out testing can be used in curtain wall and façade anchoring applications. The testing method and acceptance criteria must follow the project requirements.
Why is alignment important during pull-out testing?
Poor alignment may introduce bending or side loading instead of applying a predominantly axial tensile force, potentially affecting the test and creating an unsafe setup.
Where can I get a Langry APT200 Anchor Pull-Out Tester in Malaysia?
MTM Precision Sdn. Bhd. supplies construction testing and measurement equipment in Malaysia and can assist customers with selecting a suitable Langry anchor pull-out tester for their required test range and application.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
🌐 Website: www.mtmpre.com.my
📧 Email: mtmpre@yahoo.com
📱 WhatsApp: +6016-660 7346
For Langry APT200 Anchor Pull-Out Tester Malaysia, anchor bolt testing equipment, construction testing instruments and technical product enquiries, contact MTM Precision.