Langry APT200 for Chemical Anchor Pull-Out Testing Malaysia
Langry APT200 for Chemical Anchor Pull-Out Testing Malaysia
Chemical Anchor Pull-Out Tester Malaysia
The Langry APT200 Anchor Pull-Out Tester is a professional 200kN / 20-ton class hydraulic pull-out testing system suitable for testing installed anchoring components in construction and civil engineering applications.
One important application is the testing of chemical anchors and bonded anchoring systems.
Chemical anchors are widely used where threaded rods, reinforcing bars or other anchoring elements need to be fixed into concrete using an adhesive anchoring system.
Because the performance of a chemical anchor depends not only on the anchor material but also on drilling, hole cleaning, adhesive installation, curing and workmanship, on-site pull-out testing can play an important role in construction quality assurance.
For contractors, consultants, testing laboratories and QA/QC teams in Malaysia, the Langry APT200 provides up to 200kN measurement capacity for suitable anchor pull-out testing applications.
What Is a Chemical Anchor?
A chemical anchor, also commonly called a bonded anchor or adhesive anchor, typically uses an adhesive material to secure a threaded rod, reinforcing bar or other anchoring element inside a drilled hole.
Depending on the anchoring system, the adhesive may be supplied in forms such as:
Injection cartridges
Resin systems
Adhesive mortar
Capsule systems
After the hole is prepared and the adhesive is installed, the anchor element is inserted and the adhesive is allowed to cure.
Once properly installed and cured, the anchoring system can transfer loads into the base material.
Why Test Chemical Anchors After Installation?
The performance of an installed chemical anchor can be influenced by several factors.
These may include:
Hole diameter
Drilling method
Hole depth
Hole cleaning
Dust remaining inside the hole
Anchor embedment depth
Adhesive quantity
Adhesive mixing
Installation temperature
Curing time
Base material condition
Anchor alignment
Installer workmanship
This means that selecting a high-quality chemical anchor does not by itself guarantee that every installed anchor will perform as intended.
Where required by the project specification or engineer, on-site pull-out testing provides a method of verifying the installed anchoring system under a specified tensile load.
How Does Chemical Anchor Pull-Out Testing Work?
A pull-out tester applies tensile force to the installed anchor.
For a typical test arrangement, the anchor is connected to the hydraulic pull-out tester using an appropriate adapter and pulling assembly.
The hydraulic system then increases the tensile force in a controlled manner.
The operator monitors the applied force using the digital measuring system.
Depending on the approved test method, the test may involve:
Identifying the anchor to be tested
Inspecting the installation
Selecting the correct adapter
Positioning the pull-out tester
Aligning the tester with the anchor
Applying tensile load progressively
Reaching the specified test load
Holding the load where required
Monitoring anchor behaviour
Recording the result
Releasing the load safely
Inspecting the anchor and surrounding concrete
The required load and acceptance criteria should be established before testing.
Langry APT200 Technical Specifications
SpecificationLangry APT200Measurement Range0–200kNCapacity ClassApprox. 20 TonCylinder Center Hole35mmCylinder Stroke70mmCylinder WeightApprox. 13kgCommon AnchorageΦ6–Φ25Pull RodM24ConverterM6–M22Data Storage500 RecordsContinuous Working Time>200 HoursAccuracy ClassificationEN ISO 7500-1 Class 1
The 200kN capacity makes the APT200 suitable for many medium-to-heavy-duty anchor testing applications.
However, the maximum capacity of the instrument should never be interpreted as the required test load for every anchor.
Chemical Anchor Proof Testing
One common objective of site testing is proof testing.
In a proof test, an installed anchor is loaded to a predetermined test level according to the applicable project requirement.
The objective is generally not to intentionally destroy the anchor.
Instead, the test is used to verify that the installed anchor can withstand the specified proof load under the defined test conditions.
The actual proof load must be determined by the applicable engineering specification or approved testing procedure.
Proof Load Is Not the Same as Tester Capacity
This distinction is very important.
The Langry APT200 has a maximum measurement range of:
200kN
But this does not mean that every chemical anchor should be tested to 200kN.
For example, the required test load may be substantially below the maximum capacity of the tester depending on:
Anchor specification
Anchor diameter
Embedment depth
Base material
Design load
Project specification
Engineer's requirements
Test method
The tester provides the available measurement range.
The engineer or approved testing procedure determines the required test load.
Chemical Anchor Installation Problems That May Affect Testing
1. Poor Hole Cleaning
Dust and drilling debris remaining inside the hole may affect the bond between the adhesive and the substrate.
Hole preparation should therefore follow the anchor manufacturer's installation requirements.
2. Incorrect Hole Diameter
Using an incorrect drill size may affect the intended anchoring performance.
3. Insufficient Embedment Depth
The installed anchor should meet the specified embedment requirement.
Incorrect embedment may affect its ability to transfer tensile loads.
4. Incorrect Adhesive Installation
Improper mixing or injection can result in poor bonding.
5. Insufficient Curing Time
Testing an adhesive anchor before the required curing period has been completed may produce an invalid or misleading result.
6. Poor Base Material
Cracked, weak or deteriorated concrete may affect anchor behaviour.
7. Incorrect Installation Temperature
Some adhesive anchoring systems have specific temperature requirements for installation and curing.
8. Installation Workmanship
Incorrect procedures can reduce the performance of an otherwise correctly specified anchoring system.
Chemical Anchor vs Mechanical Anchor Pull-Out Testing
Both chemical and mechanical anchors can require tensile testing, but their anchoring mechanisms are different.
Chemical Anchors
Chemical anchors generally rely on bonding between the anchor element, adhesive and base material.
Important factors can include:
Hole cleaning
Adhesive mixing
Adhesive quantity
Curing
Embedment depth
Mechanical Anchors
Mechanical anchors may rely on mechanisms such as expansion, undercutting or other mechanical engagement with the base material.
Important factors can include:
Hole diameter
Embedment
Installation torque
Expansion setting
Concrete condition
The Langry APT200 can be used as part of an appropriate pull-out testing setup for suitable anchoring applications.
Typical Applications in Malaysia
Chemical anchors are used across many types of construction work.
Potential applications include:
Structural steel installation
Equipment base fixing
Machinery anchoring
Façade installation
Curtain wall anchoring
Handrail installation
Barrier installation
Building services support
M&E installation
Signage structures
Retrofit construction
Reinforcement connections
Infrastructure works
Renovation and strengthening projects
Where the project requires verification of installed anchor performance, pull-out testing may form part of the QA/QC process.
Chemical Anchor Testing for Façade and Curtain Wall Works
Façade systems frequently depend on anchors and brackets connected to the building structure.
Because these fixings form part of the load-transfer system, installation quality can be important.
Pull-out testing may therefore be specified for selected façade or curtain wall anchors.
The Langry APT200 offers up to 200kN testing capacity for suitable applications.
Actual testing must follow the façade engineer's or project's approved method and acceptance criteria.
Chemical Anchor Testing for Structural Steel Installation
Structural steel frames, brackets and support structures may use post-installed anchors where connections to existing concrete are required.
Where specified, pull-out testing can help verify selected installed anchors before subsequent works continue.
This can be particularly useful for:
Steel columns
Steel brackets
Support frames
Equipment supports
Retrofitting works
Structural strengthening works
Chemical Anchor Testing for M&E Installations
Mechanical and electrical installations can also involve anchored supports.
Examples include:
Pipe supports
Cable tray supports
Mechanical equipment
HVAC supports
Electrical equipment frames
Building service brackets
The required testing level depends on the project and engineering requirements.
What Happens If a Chemical Anchor Fails the Pull-Out Test?
A failed pull-out test should be investigated systematically.
Possible causes may include:
Incorrect installation
Poor hole cleaning
Insufficient curing
Wrong adhesive
Incorrect hole size
Insufficient embedment
Damaged concrete
Incorrect anchor specification
Installation workmanship
Test setup issues
The failed anchor should not simply be retested repeatedly without understanding the reason for the failure.
Where necessary, the contractor, engineer and anchor supplier should review the installation and test conditions.
Why Choose the Langry APT200 for Chemical Anchor Testing?
The APT200 offers several practical advantages for professional users.
200kN Measurement Range
The system provides up to 200kN measurement capacity.
Portable Field Testing
It is designed for use at construction sites and inspection locations.
Digital Measurement
The electronic indicator provides digital monitoring of the applied force.
Data Storage
Up to 500 measurement records can be stored.
Suitable Capacity for Professional Testing
The 200kN range provides useful capacity for contractors and testing companies handling different anchor testing requirements.
Who Needs a Chemical Anchor Pull-Out Tester?
Potential users include:
Main contractors
Civil engineering contractors
Structural contractors
Façade contractors
Curtain wall contractors
Steel structure contractors
M&E contractors
Anchor installation specialists
QA/QC departments
Engineering consultants
Inspection companies
Testing laboratories
Government project contractors
Infrastructure contractors
For companies regularly performing anchor installation or inspection, owning a suitable pull-out tester can provide greater flexibility for site testing.
Choosing Between Langry APT100, APT200 and APT300
Langry provides different capacities in the APT series.
ModelMaximum Measurement RangeApproximate CapacityAPT100100kN10 TonAPT200200kN20 TonAPT300300kN30 Ton
The correct model should be selected according to the anticipated test load and application.
For users who require more capacity than a 100kN system while still wanting a relatively portable field tester, the APT200 can be a practical choice.
Frequently Asked Questions About Chemical Anchor Pull-Out Testing
Can the Langry APT200 test chemical anchors?
Yes. The APT200 can be used for suitable anchor pull-out testing applications when equipped with the appropriate test arrangement and accessories.
What is the maximum testing range?
The APT200 provides a maximum measurement range of 200kN.
Is 200kN equal to 20 tons?
200kN is approximately 20.4 metric tonnes-force, so the APT200 is commonly described as a 20-ton class pull-out tester.
Should every chemical anchor be tested to 200kN?
No. The required test load depends on the anchor system and project requirements. 200kN is the instrument's maximum measurement capacity.
Can a chemical anchor be tested immediately after installation?
The anchoring system must meet the required curing conditions before testing. Always follow the chemical anchor manufacturer's installation instructions and the approved project test procedure.
Why can chemical anchors fail pull-out testing?
Potential causes include poor hole cleaning, incorrect embedment, insufficient curing, improper adhesive installation, weak substrate or incorrect anchor selection.
Can the APT200 be used for construction QA/QC?
Yes. Pull-out testing is one method that may be used as part of construction quality control where anchor verification is required.
Where can I buy a chemical anchor pull-out tester in Malaysia?
MTM Precision Sdn. Bhd. supplies construction testing and measurement equipment in Malaysia, including Langry anchor pull-out testing solutions.
Langry Anchor Pull-Out Tester Supplier Malaysia
Choosing the correct pull-out tester involves more than selecting the highest capacity.
Users should consider:
Required test load
Anchor diameter
Anchor type
Available exposed thread
Test location
Reaction arrangement
Required accessories
Project test method
MTM Precision can assist customers in identifying an appropriate Langry APT configuration based on their testing application.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
🌐 Website: www.mtmpre.com.my
📧 Email: mtmpre@yahoo.com
📱 WhatsApp: +6016-660 7346
For Langry APT200 Chemical Anchor Pull-Out Tester Malaysia, anchor testing equipment, construction testing instruments and product enquiries, contact MTM Precision.
11 Aug 2026