Langry APT200 for Rebar and Steel Bar Pull-Out Testing Malaysia
Langry APT200 for Rebar and Steel Bar Pull-Out Testing Malaysia
200kN Rebar Pull-Out Tester Malaysia
The Langry APT200 Anchor Pull-Out Tester is a professional hydraulic testing system with a maximum measurement range of 200kN, approximately equivalent to a 20-ton class pull-out tester.
The system is designed for pull-out testing applications involving suitable anchor rods, steel bars, expansion bolts and other anchoring components.
For construction contractors, engineering consultants, inspection companies and QA/QC teams in Malaysia, the Langry APT200 can provide a practical field testing solution where the pull-out resistance of an installed steel bar or anchoring element needs to be evaluated.
What Is Rebar Pull-Out Testing?
The term rebar pull-out test can describe different types of testing, so the test objective should be clearly defined.
In construction site applications, it may refer to applying tensile load to a reinforcing bar or steel bar that has been post-installed or anchored into concrete.
The purpose may be to verify whether the installed anchoring system can withstand a specified tensile test load.
This type of field verification should not automatically be confused with a controlled laboratory rebar-to-concrete bond strength test, which may require a specific specimen geometry, loading method, displacement measurement and applicable test standard.
The Langry APT200 is primarily a portable pull-out testing system for suitable field anchorage testing applications.
Why Test Post-Installed Rebar?
Post-installed reinforcing bars can be used in construction, extension, strengthening and retrofit applications.
Examples may include:
Structural extensions
Concrete strengthening
New-to-existing concrete connections
Building modification
Retrofit construction
Structural repair
Additional concrete elements
Anchored steel bars
Connection works
Where required by the project engineer or specification, selected installed bars may need to be tested to verify their anchorage performance.
How Does a Rebar Pull-Out Test Work?
The basic principle involves connecting the exposed steel bar to a hydraulic pull-out testing system and applying a controlled axial tensile load.
A typical field procedure may include:
Identifying the steel bar
Confirming the bar diameter
Recording the test location
Inspecting the surrounding concrete
Confirming the required test load
Selecting a suitable pulling connection
Positioning the hydraulic cylinder
Aligning the pulling system
Applying tensile load progressively
Monitoring the applied force
Holding the specified load if required
Recording observations
Releasing the hydraulic pressure safely
Inspecting the bar and substrate after testing
The actual procedure must follow the applicable project specification and approved test method.
Langry APT200 Technical Specifications
SpecificationLangry APT200Measurement Range0–200kNApproximate Capacity20 TonCylinder Center Hole35mmCylinder Stroke70mmCylinder WeightApprox. 13kgCommon AnchorageΦ6–Φ25Pull RodM24ConverterM6–M22Data Storage500 RecordsContinuous Working Time>200 HoursAccuracy ClassificationEN ISO 7500-1 Class 1
The 200kN measurement range makes the APT200 suitable for a variety of medium-to-heavy-duty anchorage testing applications.
Post-Installed Rebar and Chemical Anchoring
Post-installed reinforcing bars are often installed into drilled holes using an approved bonding or anchoring system.
The performance of the completed installation may depend on several factors.
These can include:
Correct hole diameter
Drilling method
Drilling depth
Hole cleaning
Bar diameter
Embedment depth
Adhesive selection
Adhesive installation
Curing time
Installation temperature
Concrete condition
Installer workmanship
Because installation conditions matter, testing selected installed bars may be specified as part of project QA/QC.
Why Hole Cleaning Matters
Hole cleaning can be particularly important for bonded post-installed anchoring systems.
Drilling creates dust and debris inside the hole.
If the anchoring system requires a particular cleaning procedure and that procedure is not followed, the bond condition may be affected.
The installation team should therefore follow the anchor or adhesive manufacturer's approved installation procedure.
A pull-out tester should not be treated as a substitute for correct installation practice.
Testing verifies the installation under the specified test conditions; it does not make a poorly installed anchor acceptable.
Why Embedment Depth Matters
Embedment depth is another important consideration in anchorage performance.
A deeper embedment does not automatically mean that every installation will achieve the same result, because performance also depends on the anchoring system, substrate and installation conditions.
Likewise, an insufficient embedment depth may prevent an installed bar from achieving its intended performance.
The actual required embedment should follow the engineering design and anchoring system requirements.
Proof Testing of Installed Steel Bars
A project may specify a proof test for selected post-installed bars.
In this type of test, a predetermined tensile load is applied according to the approved testing procedure.
The load may need to be maintained for a specified period while the operator monitors the installation.
The purpose is generally to verify the installed anchorage against defined project criteria rather than intentionally pull the bar to destruction.
Proof Testing vs Ultimate Pull-Out Testing
These are different test objectives.
Proof Test
A proof test typically checks whether an installed anchoring element can withstand a predetermined test load.
The intention is normally not to cause failure.
Ultimate Pull-Out Test
An ultimate test investigates behaviour at higher loads until a specified failure criterion occurs.
Possible observations may include:
Bar pull-out
Bond failure
Concrete breakout
Steel failure
Excessive movement
Other anchorage failure modes
Ultimate testing should be performed only under an appropriate engineering test plan.
200kN Is the Tester Capacity – Not the Required Rebar Test Load
The Langry APT200 has a maximum measurement range of:
0–200kN
This does not mean that every steel bar should be tested to 200kN.
The correct test load depends on factors such as:
Bar diameter
Steel properties
Anchoring system
Embedment depth
Concrete condition
Design requirement
Project specification
Engineer's approved test procedure
The tester provides the available force measurement capacity.
The project requirements determine how much load should actually be applied.
Can the APT200 Test Φ6 to Φ25 Anchoring Components?
The manufacturer's specifications list a common anchorage range of Φ6–Φ25 for the APT200 configuration.
However, diameter alone should not be used to determine whether a particular test can be performed.
Users must also consider:
Required test load
Connection method
Available exposed bar length
Adapter configuration
Reaction setup
Test geometry
Site accessibility
For unusual applications, the complete setup should be reviewed before testing.
Common Causes of Poor Rebar Pull-Out Test Results
Poor Hole Cleaning
Residual drilling dust can affect some bonded anchoring installations.
Insufficient Embedment
Incorrect embedment may reduce anchorage performance.
Incorrect Adhesive Installation
Improper mixing, dispensing or injection can affect bonding.
Insufficient Curing
Testing before the required curing period is complete may produce an unreliable result.
Incorrect Hole Diameter
The drilled hole should meet the anchoring system's requirements.
Poor Concrete Condition
Weak, cracked or deteriorated substrate can influence the result.
Incorrect Bar Preparation
The anchoring system may require specific preparation of the steel element.
Installation Workmanship
The final performance of a post-installed anchoring system depends heavily on correct installation.
Rebar Pull-Out Testing for Structural Extension Works
Building extension projects may require new concrete elements to be connected to an existing structure.
Post-installed bars can be used as part of these connections where specified by the structural design.
Typical applications may include:
New slabs
Additional beams
Wall extensions
Structural strengthening
Concrete extensions
Retrofit connections
Where verification is required, selected bars may be subjected to pull-out testing before subsequent construction proceeds.
Rebar Pull-Out Testing for Renovation and Retrofitting
Existing buildings frequently undergo modification.
New structural or supporting elements may need to connect to existing concrete.
This can create demand for:
Post-installed rebar
Chemical anchoring
Steel bar anchorage
Pull-out testing
Site verification
For contractors handling retrofit projects, a portable tester such as the Langry APT200 can provide a useful field-testing capability.
Rebar Pull-Out Testing for Infrastructure Projects
Post-installed anchoring systems can also be encountered in infrastructure projects.
Depending on the design, applications may involve:
Bridges
Retaining structures
Concrete structures
Utility structures
Structural modification
Repair works
Strengthening projects
Testing requirements vary significantly between projects, so the approved specification should always be followed.
Importance of Proper Alignment
The pulling force should be applied as axially as practical to the steel bar.
Poor alignment can introduce unwanted bending or side loading.
This may:
Influence the test result
Damage the pulling connection
Damage the bar
Create an unstable setup
Increase safety risk
The test arrangement should therefore be properly positioned before substantial tensile load is applied.
Reaction Setup Is Important
The hydraulic cylinder requires a stable reaction arrangement.
The reaction setup can affect how forces are transferred into the surrounding concrete.
The operator should consider:
Surface condition
Anchor position
Distance from concrete edges
Nearby anchors
Local concrete condition
Test fixture geometry
A poorly designed reaction arrangement can affect the test and should be avoided.
What Should Be Included in a Rebar Pull-Out Test Record?
A professional test record may include:
Project name
Test location
Bar identification
Bar diameter
Installation method
Anchoring material
Embedment information
Base material
Installation date
Test date
Required test load
Maximum applied load
Holding period
Observed movement
Visible cracking or damage
Test result
Operator details
Equipment identification
The Langry APT series supports storage of up to 500 measurement records, which can assist with test data management.
Safety During Rebar Pull-Out Testing
A 200kN hydraulic pull-out tester can generate substantial force.
Operators should:
Wear appropriate PPE
Inspect the equipment before use
Confirm all pulling connections
Check the hydraulic system
Maintain correct alignment
Establish a safe working area
Keep personnel away from the potential failure path
Avoid exceeding equipment limits
Follow the manufacturer's instructions
Follow the approved project test method
A bar, adapter or connection failing under high tensile load can present a serious hazard.
Why Choose Langry APT200 for Field Testing?
The Langry APT200 combines:
200kN maximum measurement range
Approximately 20-ton class capacity
Portable hydraulic loading
Digital force indication
70mm cylinder stroke
35mm cylinder centre hole
Data storage for up to 500 records
Long operating time
This makes it a practical option for contractors and inspection teams that require professional anchor and steel bar pull-out testing capability on site.
Langry APT100 vs APT200 vs APT300
ModelMaximum RangeApproximate CapacityAPT100100kN10 TonAPT200200kN20 TonAPT300300kN30 Ton
The correct model should be selected based primarily on the anticipated test load and test configuration.
The APT200 provides a useful middle range for users who require more capacity than a 100kN tester but do not necessarily need a 300kN system.
Frequently Asked Questions
Can the Langry APT200 test rebar?
The APT series is designed for suitable pull-out testing applications involving steel bars and anchoring components. The actual setup must be compatible with the bar, required load and test method.
What is the maximum load range of the APT200?
The APT200 has a maximum measurement range of 200kN, approximately a 20-ton class system.
Does every rebar need to be tested to 200kN?
No. The required load must follow the engineering design, anchoring system, project specification and approved test method.
Can the APT200 test post-installed rebar?
It can be used for suitable field pull-out testing of post-installed anchoring elements when the required connection, reaction arrangement and test method are appropriate.
Is rebar pull-out testing the same as a laboratory bond strength test?
Not necessarily. A field pull-out verification test and a controlled laboratory rebar-concrete bond test may have different objectives, specimen configurations, measurements and standards.
Can the tester be used on construction sites?
Yes. The Langry APT series is intended for portable field testing applications.
Where can I buy a 200kN rebar pull-out tester in Malaysia?
MTM Precision Sdn. Bhd. supplies Langry anchor pull-out testing equipment and other construction testing instruments in Malaysia.
Rebar and Anchor Pull-Out Tester Supplier Malaysia
Before purchasing a pull-out tester, provide the supplier with as much application information as possible.
Useful information includes:
What are you testing?
Bar or anchor diameter
Expected test load
Required maximum load
Exposed bar or thread size
Base material
Test location
Required test method
This makes it easier to determine whether the Langry APT100, APT200 or APT300 is suitable for the application.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
🌐 Website: www.mtmpre.com.my
📧 Email: mtmpre@yahoo.com
📱 WhatsApp: +6016-660 7346
For Langry APT200 Rebar and Steel Bar Pull-Out Tester Malaysia, anchor testing equipment, construction testing instruments and product enquiries, contact MTM Precision.
11 Aug 2026