Langry APT200 for Expansion Bolt and Mechanical Anchor Pull-Out Testing Malaysia
Langry APT200 for Expansion Bolt and Mechanical Anchor Pull-Out Testing Malaysia
Mechanical Anchor Pull-Out Tester Malaysia
The Langry APT200 Anchor Pull-Out Tester is a professional 200kN / 20-ton class hydraulic pull-out testing system designed for evaluating suitable installed anchors, anchor rods, steel bars, expansion bolts and related anchoring components.
One of its important construction applications is expansion bolt and mechanical anchor pull-out testing.
Mechanical anchors are widely used throughout building, civil engineering, structural steel, M&E, façade and infrastructure projects in Malaysia.
Because actual anchor performance can be influenced by installation quality, concrete condition, embedment depth and other site factors, pull-out testing may be specified as part of project QA/QC and inspection requirements.
The Langry APT200 provides up to 200kN measurement capacity for suitable anchor testing applications.
What Is a Mechanical Anchor?
A mechanical anchor is a fixing system that transfers load into a base material through a mechanical anchoring mechanism.
Depending on the design, this may involve expansion, wedging, undercutting or another form of mechanical engagement.
Common applications include fixing:
Steel brackets
Structural components
Machinery
Equipment bases
Handrails
Barriers
Façade brackets
Pipe supports
Cable supports
Building services
Sign structures
Safety systems
Different mechanical anchor designs have different installation and testing requirements.
What Is an Expansion Anchor?
An expansion anchor is a type of mechanical anchor designed to develop anchorage by expanding against the wall of a drilled hole.
Correct installation is important.
The actual performance may depend on factors including:
Correct drill diameter
Hole depth
Embedment depth
Concrete strength
Concrete condition
Edge distance
Anchor spacing
Installation torque
Correct expansion setting
Installer workmanship
For this reason, project engineers may specify on-site pull-out testing for selected installed anchors.
Why Perform Expansion Bolt Pull-Out Testing?
A product specification tells the engineer how an anchor system is expected to perform under defined conditions.
Site conditions, however, may be different.
An installed anchor can be affected by:
Incorrect drilling
Oversized holes
Insufficient embedment
Poor substrate
Installation errors
Incorrect tightening
Damaged anchors
Concrete cracking
Pull-out testing provides a method of applying a controlled tensile force to the installed anchor and observing its performance under the specified test conditions.
How Does Mechanical Anchor Pull-Out Testing Work?
The basic principle is straightforward.
The installed anchor is connected to the pull-out testing equipment using a suitable adapter and pulling arrangement.
A hydraulic cylinder then applies tensile force to the anchor.
The digital measuring system displays the applied load.
A typical procedure may involve:
Identifying the anchor
Recording the test location
Inspecting the surrounding concrete
Selecting the correct adapter
Installing the pull-out test arrangement
Aligning the hydraulic cylinder
Applying the load progressively
Reaching the specified proof or test load
Holding the load if required
Observing anchor behaviour
Recording the result
Releasing the load safely
Inspecting the anchor after testing
The exact procedure must follow the applicable project specification and approved test method.
Langry APT200 Technical Specifications
SpecificationLangry APT200Measurement Range0–200kNApproximate Capacity20 TonCylinder Center Hole35mmCylinder Stroke70mmCylinder WeightApprox. 13kgCommon AnchorageΦ6–Φ25Pull RodM24ConverterM6–M22Data Storage500 RecordsContinuous Working Time>200 HoursAccuracy ClassificationEN ISO 7500-1 Class 1
The 200kN capacity provides useful flexibility for professional construction testing applications.
200kN Tester Does Not Mean Every Anchor Is Tested to 200kN
This is one of the most important points when selecting or using an anchor pull-out tester.
The 200kN rating represents the maximum measurement range of the Langry APT200.
It does not mean that every expansion bolt or mechanical anchor should be pulled to 200kN.
The actual required test load depends on factors such as:
Anchor type
Anchor diameter
Design load
Anchor specification
Base material
Project specification
Engineer's requirements
Approved testing method
The tester provides the capacity.
The test specification determines the load.
Proof Testing of Mechanical Anchors
For many construction projects, the objective may be to verify that selected installed anchors can withstand a predetermined proof load.
The anchor is loaded according to the approved procedure and monitored for unacceptable behaviour.
The test may require the load to be held for a specified period.
The acceptance criteria should be established before testing begins.
The operator should not create a pass/fail criterion based only on the capacity of the pull-out tester.
Pull-Out Testing to Failure
Some engineering investigations may require an anchor to be tested beyond a normal proof load until a defined failure criterion is reached.
This is different from routine proof testing.
Possible failure modes can include:
Anchor pull-out
Concrete breakout
Anchor steel failure
Excessive displacement
Local substrate damage
Failure of the anchoring mechanism
Destructive or ultimate testing should only be performed according to an appropriate engineering test plan.
Common Mechanical Anchor Installation Problems
Incorrect Hole Diameter
A drilled hole that is too large or too small can affect the installation and performance of an expansion anchor.
Insufficient Embedment
If the anchor is not installed to the required embedment depth, its load-transfer behaviour may be affected.
Incorrect Installation Torque
Some mechanical anchors require a specified tightening torque to achieve the intended expansion or clamping condition.
Poor Concrete Condition
Weak, cracked or damaged concrete can influence anchorage performance.
Incorrect Anchor Setting
An expansion anchor that has not been correctly set may not develop the intended anchorage.
Edge Distance
Anchors installed too close to a concrete edge may behave differently from anchors installed in a large concrete area.
Anchor Spacing
Closely spaced anchors can interact with the surrounding concrete.
Poor Workmanship
Installation quality remains an important factor even when the correct anchor has been specified.
Expansion Anchor vs Chemical Anchor
Both systems are commonly used for post-installed anchoring, but their mechanisms differ.
Mechanical / Expansion AnchorChemical / Bonded AnchorUses mechanical anchoring actionUses adhesive bondingSetting may depend on expansion mechanismPerformance depends strongly on bonding and curingInstallation torque may be importantHole cleaning and adhesive installation are criticalNo adhesive curing period for many systemsSpecified curing time is normally requiredSuitable for many construction fixingsCommon for structural and retrofit anchoring
Both systems may require pull-out testing depending on the project specification.
Applications for Mechanical Anchor Testing in Malaysia
Structural Steel Installation
Mechanical anchors are frequently used for fixing steel components and brackets to concrete structures.
Pull-out testing may be required to verify selected installations.
Handrail and Balustrade Installation
Handrails and barriers rely on secure connections to the supporting structure.
Testing may be specified for critical fixing points.
Façade and Curtain Wall Works
Façade brackets and related components may use post-installed anchors.
Pull-out testing can form part of the project inspection process.
Machinery Installation
Industrial machinery, equipment frames and support structures may be anchored to concrete foundations.
M&E Supports
Mechanical anchors are commonly used for:
Pipe supports
Cable trays
HVAC supports
Equipment frames
Building service brackets
Signage and Structural Supports
Large signs and supporting frames may also require anchor verification depending on the project design.
Infrastructure Projects
Anchoring systems are used throughout infrastructure works where reliable fixing to concrete structures is required.
What Should Be Recorded During a Pull-Out Test?
Professional test documentation may include:
Project name
Test location
Anchor number
Anchor type
Anchor diameter
Manufacturer
Base material
Installation information
Required test load
Maximum applied load
Holding time
Observed movement
Visible damage
Test result
Operator details
Testing equipment identification
The Langry APT series provides storage for up to 500 measurement records, helping users manage force measurement information during testing.
What Happens If an Expansion Bolt Fails a Pull-Out Test?
A failed test should be investigated rather than immediately assuming the anchor itself is defective.
Potential causes include:
Incorrect drill size
Poor concrete
Insufficient embedment
Incorrect installation
Incorrect tightening torque
Damaged anchor
Incorrect anchor selection
Edge effects
Test setup problems
Poor alignment during testing
The engineer or responsible project team should determine the appropriate corrective action.
Why Correct Pull-Out Tester Alignment Matters
A pull-out test is intended to apply a controlled tensile force to the anchor.
Poor alignment can introduce unwanted side loading or bending.
This may:
Affect the measured result
Damage the anchor
Damage the adapter
Create an unstable test arrangement
Increase safety risk
The hydraulic cylinder and pulling assembly should therefore be positioned as concentrically as practical with the anchor being tested.
Why Choose the Langry APT200?
The Langry APT200 provides a practical combination of measurement capacity, portability and digital force measurement.
Key advantages include:
Up to 200kN measurement range
Approximately 20-ton class capacity
Digital load indication
70mm hydraulic cylinder stroke
35mm cylinder centre hole
Data storage up to 500 records
Long operating time
Suitable for professional site testing
For companies testing a range of anchors, 200kN provides considerably more testing capability than a smaller 100kN system.
Langry APT100 vs APT200 vs APT300
ModelMaximum RangeApproximate CapacityAPT100100kN10 TonAPT200200kN20 TonAPT300300kN30 Ton
Choosing the correct model should be based on the maximum anticipated test load, not simply on anchor diameter.
For many contractors, inspection companies and testing laboratories, the APT200 can provide a useful middle-capacity option.
Who Should Consider the Langry APT200?
The APT200 may be suitable for:
Main contractors
Civil engineering contractors
Structural contractors
Steel structure contractors
Anchor installation specialists
Façade contractors
Curtain wall contractors
M&E contractors
QA/QC departments
Engineering consultants
Inspection companies
Testing laboratories
Infrastructure contractors
Frequently Asked Questions
Can the Langry APT200 test expansion bolts?
Yes. The APT series is intended for pull-out testing of suitable anchoring components including expansion bolts when the correct adapter and test arrangement are used.
What is the maximum capacity of the APT200?
The Langry APT200 has a maximum measurement range of 200kN, approximately equivalent to a 20-ton class tester.
Do I test an expansion bolt to 200kN?
Not automatically. The required test load must be determined from the anchor specification, project requirements and approved testing procedure.
Can the APT200 test mechanical anchors on site?
Yes. The system is designed for field applications and can be used for appropriate on-site anchor pull-out testing.
Can the same tester be used for chemical and mechanical anchors?
A suitable pull-out testing system may be used for different anchoring applications when the required load range, adapter, reaction arrangement and approved test method are appropriate.
What can cause an expansion bolt to fail a pull-out test?
Possible factors include incorrect hole size, insufficient embedment, poor concrete, incorrect setting, installation errors and inappropriate anchor selection.
Is pull-out testing destructive?
Not necessarily. A proof test may apply a predetermined load without intentionally loading the anchor to failure. Ultimate or failure testing is a different procedure.
Where can I buy an expansion bolt pull-out tester in Malaysia?
MTM Precision Sdn. Bhd. supplies Langry construction testing and anchor pull-out testing equipment in Malaysia.
Anchor Pull-Out Tester Supplier Malaysia
Choosing an anchor pull-out tester should consider the complete testing application.
Before selecting equipment, users should know:
Anchor type
Anchor diameter
Required test load
Available exposed thread or connection
Test location
Base material
Required adapter
Project testing method
MTM Precision can assist customers in selecting an appropriate Langry APT100, APT200 or APT300 according to the required testing range and application.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
🌐 Website: www.mtmpre.com.my
📧 Email: mtmpre@yahoo.com
📱 WhatsApp: +6016-660 7346
For Langry APT200 Expansion Bolt and Mechanical Anchor Pull-Out Tester Malaysia, construction testing equipment and anchor testing enquiries, contact MTM Precision.
11 Aug 2026