UV Energy Meter for UV LED Printing Machine Linshang LS137 Malaysia

UV Energy Meter for UV LED Printing Machine – Linshang LS137 Malaysia   Modern UV LED printing machines can cure ink almost immediately after printing, allowing faster production, printing on a wider range of substrates and reduced waiting time compared with conventional drying processes.   However, fast curing depends on one critical factor:   The printed surface must receive sufficient and consistent UV exposure.   If UV output, conveyor speed, exposure time or curing distance changes, print quality may also change—even when the UV LED lamps still appear to be operating normally.   The Linshang LS137 UV Energy Meter is designed for UV LED curing systems and can measure UV energy, UV irradiance, peak irradiance, exposure duration and temperature.   For UV printing companies in Malaysia, it can provide useful measurement data for machine setup, quality control, troubleshooting and preventive maintenance.   Why Does a UV Printing Machine Need UV Measurement?   A UV printing machine normally has its own power settings.   Operators may see values such as:   UV Power: 60%   UV Power: 80%   UV Power: 100%   These settings are useful for operating the machine.   However, they do not directly tell you the actual UV exposure reaching the printed material.   For process verification, manufacturers may want to know:   What is the actual UV irradiance?   What is the peak UV irradiance?   How much accumulated UV energy is delivered?   How long is the exposure?   Has UV performance changed over time?   This is where a UV energy meter becomes useful.   Common UV Printing Problems Related to Curing   Depending on the ink, substrate and printing process, insufficient or inconsistent UV curing may contribute to problems such as:   Tacky ink   Ink smearing   Poor scratch resistance   Weak adhesion   Surface marking   Incomplete curing   Inconsistent gloss   Poor durability   Increased rejection   Production inconsistency   These symptoms do not automatically prove that the UV LED lamp is faulty.   The actual curing conditions should be measured and compared.   What Does Linshang LS137 Measure?   The LS137 provides several parameters useful for UV LED printing applications:   UV Energy   UV Irradiance   Peak UV Irradiance   Measurement Duration   Temperature   Maximum Temperature   Instead of checking only whether the UV LED source is ON, operators can obtain numerical data describing the curing exposure.   Designed for UV LED Curing   The Linshang LS137 has a spectral response range of approximately:   340–420 nm   It is calibrated using a:   395 nm UV LED source   This makes the LS137 particularly relevant to modern industrial UV LED curing systems, especially machines using 395 nm UV LEDs.   Common industrial UV LED wavelengths can include:   365 nm   385 nm   395 nm   405 nm   The actual wavelength of the printing machine should always be confirmed before selecting the meter.   Why 395 nm Is Important in UV Printing   395 nm UV LED technology is widely encountered in industrial UV curing equipment.   If a printing machine uses a 395 nm UV LED source, the LS137 is particularly relevant because its calibration is based on a 395 nm UV LED source.   However, wavelength is only one part of instrument selection.   Users should also consider:   Expected irradiance   Machine configuration   Available measurement space   Production speed   Measurement requirements   UV Irradiance vs UV Energy in Printing   These two measurements should not be confused.   UV Irradiance   UV irradiance describes how strong the UV radiation is at a particular moment.   It is commonly expressed in:   mW/cm²   UV Energy   UV energy describes the accumulated exposure over the curing period.   It is commonly expressed in:   mJ/cm²   For UV printing, both can be important.   Why Printing Speed Changes UV Energy   Imagine a UV printing line operating at its normal validated speed.   The ink cures correctly.   Management wants to increase production output, so the printing or conveyor speed is increased.   The UV LED power setting remains unchanged.   What happens?   The printed material may spend less time underneath the UV source.   Therefore:   Higher Production Speed → Shorter Exposure → Potentially Lower UV Energy   Peak irradiance may remain similar while accumulated energy decreases.   This is why UV energy measurement is useful when optimizing printing speed.   Example: Increasing Printing Speed   Suppose a production line is operating at:   30 m/min   The print quality is acceptable.   The company increases the speed to:   40 m/min   Afterward, some prints become slightly tacky.   Instead of immediately increasing UV power, measure the curing conditions at both speeds.   Compare:   Peak UV irradiance   Accumulated UV energy   Exposure duration   Temperature   Print result   This provides objective data for process optimization.   UV Energy and Different Ink Colours   Different inks and printing systems may have different curing characteristics.   Factors can include:   Pigment   Ink formulation   Ink thickness   Photoinitiator   UV wavelength   Substrate   Therefore, a UV energy value that works well for one printing process should not automatically be assumed suitable for every ink or product.   The appropriate curing window should be established through process qualification and product testing.   Different Substrates Can Affect the Process   UV printing may be performed on materials such as:   Plastic   Acrylic   Glass   Metal   Paper   Cardboard   Film   Labels   Packaging materials   Wood products   Changing the substrate may require changes to production settings.   UV measurements can be recorded together with the new process parameters to create a reference for each important product.   Why “Same UV Power” Doesn't Mean “Same Curing”   Consider two printing machines.   Both are set to:   UV Power = 80%   Does this mean they provide identical UV exposure?   Not necessarily.   Differences can result from:   UV LED operating hours   LED condition   Cooling performance   Optical cleanliness   Working distance   Machine design   Number of UV modules   For meaningful comparison, measure the actual UV conditions.   Comparing Two UV Printing Machines   A printing company with several machines can establish an individual baseline for each one.   For example:   Printer A   Record:   UV wavelength   UV irradiance   UV energy   Production speed   Printer B   Record the same parameters separately.   Printer C   Create another baseline.   If one printer later develops curing problems, its current measurement can be compared with its own historical data.   Check UV Output After Maintenance   UV measurement is particularly useful after:   UV LED module replacement   Optical cleaning   Cooling-system repair   Power-system maintenance   Machine adjustment   Conveyor servicing   Mechanical realignment   The objective is to confirm that the UV curing condition has returned to the expected range before full production resumes.   Check After Replacing a UV LED Module   A new UV LED module should ideally be measured when installed.   Why?   Because this provides a new baseline.   Record:   Peak UV irradiance   Accumulated UV energy   Exposure duration   Maximum temperature   Machine settings   Future measurements can then be compared against this reference.   UV LED Aging in Printing Machines   UV LED modules generally offer long operating life, but output should not be assumed to remain exactly unchanged forever.   Performance may be influenced by:   Operating hours   Thermal conditions   Cooling   Optical contamination   Electrical condition   Periodic measurement can reveal trends before curing quality becomes unacceptable.   Example of Preventive Monitoring   A printing company could establish a schedule such as:   New UV LED → Baseline   3 months → Check   6 months → Check   9 months → Check   12 months → Check   The exact interval should be based on machine usage and quality requirements.   The important point is to build historical measurement data.   LS137 High-Irradiance Capability   Industrial UV LED printing equipment can generate high irradiance.   The Linshang LS137 supports UV irradiance measurement up to:   40,000 mW/cm²   This makes it suitable for many high-intensity UV LED curing applications within its specified operating conditions.   Using LS137 for Printing QA/QC   QA personnel can record UV measurements together with print-quality results.   For example:   Machine: UV Printer 01 UV Wavelength: 395 nm UV Power: Production Setting Printing Speed: Recorded Peak UV Irradiance: Recorded UV Energy: Recorded Maximum Temperature: Recorded Print Quality: PASS   This creates a known-good production reference.   What If the UV Reading Is Lower Than Normal?   If current measurements are significantly below the historical baseline, investigate:   UV LED condition   Optical contamination   Cooling system   Power setting   Working distance   Production speed   Active UV modules   Do not automatically replace the UV LED before checking the complete system.   What If UV Measurements Are Normal but Ink Still Doesn't Cure?   This is also valuable information.   If UV measurements remain consistent with successful historical production, investigate other variables such as:   Ink batch   Ink storage   Ink thickness   Substrate   Surface preparation   Printing parameters   Material compatibility   UV measurement can therefore help separate curing-equipment problems from material-related problems.   LS137 vs LS136 for Printing Machines   Before purchasing, determine what UV technology your printer uses.   UV LED Printing Machine   Consider:   Linshang LS137   Traditional High-Pressure Mercury UV Printing Machine   Consider:   Linshang LS136   Do not choose the meter based only on the words “UV printing.”   The UV source technology matters.   Who Should Use LS137 in a Printing Company?   Potential users include:   Printing Production Managers   Process Engineers   Maintenance Engineers   QA/QC Personnel   Machine Technicians   Printing Equipment Suppliers   Technical Service Teams   It can be particularly useful for companies where UV curing quality directly affects production output and customer acceptance.   Applications   The LS137 can be considered for UV LED curing measurement in:   Digital UV printing   Label printing   Packaging printing   Industrial inkjet printing   Wide-format UV printing   UV coating   Specialty printing   Automated UV curing lines   The suitability of the meter should always be checked against the actual UV source and machine configuration.   Don't Wait for Print Failure   A reactive approach is:   Print Quality Fails → Check UV Lamp   A more controlled approach is:   Measure Good Production → Establish Baseline → Check Periodically → Detect Changes → Maintain → Verify   This helps turn UV curing from an assumed machine condition into a measurable production parameter.   Looking for a UV Energy Meter for Printing Machines in Malaysia?   MTM Precision supplies industrial testing and measurement instruments for manufacturing, printing, engineering, maintenance and quality-control applications in Malaysia.   If your company operates a UV LED printing machine, provide us with:   Printing machine brand and model   UV source type   UV wavelength   Expected UV intensity   Printing or conveyor speed   Measurement requirement   We can assist you in determining whether the Linshang LS137 UV Energy Meter is suitable for your UV printing application.   Contact MTM Precision   MTM Precision Sdn. Bhd.   Showroom & Service Centre   No. 29-1 & 29-2, Jalan Bandar 18, Pusat Bandar Puchong, 47160 Puchong, Selangor, Malaysia   馃寪 Website: www.mtmpre.com.my 馃摟 Email: mtmpre@yahoo.com 馃摫 WhatsApp: +6016-660 7346   Contact MTM Precision for Linshang LS137 UV Energy Meter enquiries, model selection, technical information and quotation in Malaysia.  

13 Aug 2026