How to Use Linshang LS196 Gloss Meter Correctly Malaysia

How to Use Linshang LS196 Gloss Meter Correctly Malaysia

 

Correct measurement technique is important when using a gloss meter for industrial quality control. Even a good instrument can produce inconsistent results if the surface is dirty, the measurement position changes or the instrument is not placed correctly.

 

The Linshang LS196 Gloss Meter is a portable 60° gloss meter with a wide 0–1000 GU measurement range, suitable for general and high-gloss surface measurement.

 

This guide explains the basic steps for obtaining more consistent gloss measurements with the LS196.

 

Step 1: Identify the Material to Be Measured

 

Before starting, confirm that gloss measurement is appropriate for the surface and application.

 

Typical applications can include suitable surfaces such as:

 

Paint

 

Coatings

 

Plastic

 

Automotive finishes

 

Metal finishing

 

Electroplated components

 

Powder coating

 

Furniture

 

Ceramic tiles

 

Stone

 

Industrial components

 

The product specification or applicable testing standard should determine the required measurement procedure.

 

Step 2: Inspect the Measurement Surface

 

The condition of the test surface can affect the result.

 

Before measuring, check for:

 

Dust

 

Fingerprints

 

Oil

 

Water

 

Surface contamination

 

Scratches

 

Uneven areas

 

If necessary, clean the surface using an appropriate method that will not alter the finish.

 

For comparative QC measurements, all samples should be prepared in the same way.

 

Step 3: Check the Instrument

 

Before important measurements, check the condition of the LS196.

 

Follow the manufacturer's recommended calibration procedure when required.

 

This is particularly important when measurements are being used for:

 

Production acceptance

 

Supplier inspection

 

Customer reports

 

Batch comparison

 

Quality investigations

 

Consistent instrument verification helps improve confidence in the results.

 

Step 4: Define the Measurement Location

 

One of the most common causes of different gloss readings is measuring different locations.

 

A surface that appears uniform may actually have local variations.

 

For repetitive QC, establish fixed measurement points.

 

For example:

 

Point A – Top

 

Point B – Centre

 

Point C – Bottom

 

Use the same locations whenever comparing similar products.

 

Step 5: Place the LS196 Properly

 

Position the gloss meter firmly against the test surface.

 

Avoid:

 

Tilting the instrument

 

Moving it during measurement

 

Measuring across an unstable surface

 

Allowing gaps between the instrument and sample

 

Proper positioning is especially important when comparing small differences between samples.

 

Step 6: Take More Than One Reading

 

For many industrial applications, one measurement should not automatically represent an entire product.

 

Consider taking several readings.

 

For example:

 

Measurement 1 → Record

 

Measurement 2 → Record

 

Measurement 3 → Record

 

Compare the results to understand the uniformity of the surface.

 

For larger products, additional measurement locations may be required.

 

Step 7: Compare With a Reference

 

A gloss value becomes more useful when it has something to compare against.

 

Manufacturers can use:

 

Customer specification

 

Internal specification

 

Approved golden sample

 

Previous production batch

 

Supplier reference sample

 

This helps determine whether a measured value is acceptable for the actual application.

 

Step 8: Use QC Mode for Routine Inspection

 

The Linshang LS196 provides a QC mode.

 

Once appropriate acceptance limits are established, operators can compare production measurements against those requirements.

 

This is useful for repetitive applications such as:

 

Incoming inspection

 

Production QC

 

Final inspection

 

Supplier inspection

 

Batch comparison

 

It can reduce dependence on individual visual judgement.

 

Step 9: Record the Measurement Results

 

For professional QA/QC work, do not rely only on the number displayed at the time of measurement.

 

Record important information such as:

 

Product model

 

Batch number

 

Date

 

Measurement location

 

Operator

 

GU value

 

Acceptance result

 

The LS196 supports computer connection and data transmission, allowing results to be exported for further processing and analysis.

 

Step 10: Analyse Unexpected Results

 

If a gloss reading is significantly different from normal, repeat the measurement before rejecting the product.

 

Check:

 

Surface cleanliness

 

Measurement location

 

Instrument positioning

 

Calibration condition

 

Surface curvature

 

Actual production variation

 

If repeated measurements confirm the difference, investigate the manufacturing process.

 

Common Mistake: Measuring a Dirty Surface

 

Fingerprints can be particularly noticeable on glossy surfaces.

 

If one sample is clean and another contains fingerprints or oil, the readings may not be directly comparable.

 

Surface preparation should therefore be part of the company's measurement procedure.

 

Common Mistake: Changing Measurement Positions

 

Measuring the centre of one sample and the edge of another can introduce unnecessary variation.

 

Mark or define standard inspection locations whenever possible.

 

This becomes especially important when several operators use the same instrument.

 

Common Mistake: Relying on One Reading

 

A single measurement may miss local variation.

 

Multiple readings can help identify:

 

Uneven coating

 

Polishing differences

 

Surface defects

 

Mold variation

 

Production inconsistency

 

The required number of readings should be determined according to the product and QC procedure.

 

Common Mistake: Comparing Different Surface Types

 

Gloss readings should be interpreted within the context of the material and applicable measurement method.

 

Do not assume that the same numerical value has the same quality meaning for every product.

 

A gloss requirement should be established specifically for the surface being inspected.

 

Why the LS196 Is Useful for High-Gloss Surfaces

 

One of the main features of the Linshang LS196 is its wide 0–1000 GU measurement range.

 

This provides additional flexibility when measuring highly glossy and reflective surfaces.

 

Typical applications can include:

 

High-gloss coatings

 

Automotive finishes

 

Glossy plastics

 

Polished surfaces

 

Electroplated components

 

Decorative finishes

 

The same instrument can also be used for many conventional gloss measurement applications.

 

Create a Standard Gloss Measurement SOP

 

For factories using the LS196 regularly, a written measurement SOP can improve consistency.

 

The procedure can define:

 

Surface preparation

 

Instrument check

 

Calibration procedure

 

Measurement locations

 

Number of readings

 

Acceptance limits

 

Data-recording method

 

Action for out-of-specification results

 

This helps ensure that different operators follow the same measurement process.

 

Linshang LS196 Gloss Meter Supplier Malaysia

 

For Malaysian manufacturers and QA/QC departments, the Linshang LS196 provides a practical solution for objective surface gloss measurement.

 

Correct measurement technique, consistent inspection locations and proper data recording can help users obtain more meaningful results from the instrument.

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd.

Showroom & Service Centre

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia

 

🌐 Website: www.mtmpre.com.my

📧 Email: mtmpre@yahoo.com

📱 WhatsApp: +6016-660 7346


 

16 Aug 2026