How to Read a Vibration Meter: Understanding mm/s Vibration Readings Malaysia
You place a vibration meter on an electric motor and the display shows:
2.6 mm/s
What does that number actually mean?
This is one of the most important questions for technicians who are beginning to use vibration measurement for machine maintenance.
A vibration meter can provide a numerical reading, but the number becomes useful only when you understand what parameter is being measured, where the measurement was taken, how the machine was operating and how the reading compares with previous measurements or applicable criteria.
For maintenance engineers in Malaysia, learning how to interpret basic vibration readings is the first step toward practical machine condition monitoring.
What Does mm/s Mean?
mm/s means millimetres per second.
In vibration measurement, it is commonly used as a unit of vibration velocity.
Velocity describes how quickly the vibrating surface moves.
For many rotating machines, overall vibration velocity is commonly used as an indicator of general machine vibration condition.
Typical applications include:
Electric motors
Pumps
Fans
Blowers
Compressors
Gearboxes
Generators
HVAC equipment
What Does a 2.0 mm/s Reading Mean?
By itself, 2.0 mm/s provides only limited information.
Before deciding whether it is acceptable, ask:
What machine was measured?
Where was the measurement taken?
What direction was measured?
What was the machine speed?
What was the operating load?
Is the value RMS or another representation?
What was the previous reading?
What criteria apply to this machine?
The same vibration value should not automatically be interpreted identically for every machine.
Don't Judge a Machine from One Number
Suppose Motor A measures:
2.5 mm/s
Is it good or bad?
You need more context.
If Motor A normally operates around:
2.3–2.6 mm/s
and has remained stable for a long period, the reading may not represent a significant change.
But if the motor normally measures:
0.9–1.1 mm/s
and suddenly reaches:
2.5 mm/s
the change may deserve investigation.
This is why vibration trending is so valuable.
What Is Vibration Velocity?
Vibration velocity is one of the most commonly used parameters for general rotating machinery condition assessment.
It is frequently expressed as:
mm/s RMS
Depending on the vibration meter and application, other units or measurement representations may also be available.
Always check the instrument setting before recording the measurement.
What Does RMS Mean?
RMS stands for:
Root Mean Square
It is a commonly used way of expressing vibration magnitude.
For example:
Velocity: 2.8 mm/s RMS
When comparing historical measurements, make sure the readings use the same measurement basis.
Do not mix different parameters or measurement representations without understanding the difference.
mm/s vs m/s²
These units do not represent the same vibration parameter.
mm/s
Usually represents:
Vibration Velocity
m/s²
Usually represents:
Vibration Acceleration
A reading of:
3.0 mm/s
cannot simply be compared numerically with:
3.0 m/s²
They measure different aspects of vibration.
What Does g Mean on a Vibration Meter?
Some vibration meters display acceleration in:
g
This is another unit used for vibration acceleration.
Acceleration is particularly relevant to higher-frequency vibration and can provide useful information in certain bearing and mechanical applications.
Again, do not compare a value in g directly with a velocity value in mm/s.
What Does µm Mean?
µm means micrometre.
It is commonly used for vibration displacement.
Displacement describes the physical movement associated with vibration.
It may be particularly useful for certain lower-frequency or machine-specific vibration applications.
Check the Parameter Before Measuring
Before placing the vibration meter on the machine, confirm whether you are measuring:
Velocity
Acceleration
or:
Displacement
A technician can easily record the wrong information if the meter is left in a different measurement mode.
This becomes especially problematic when building historical trends.
Where Should You Measure Motor Vibration?
For electric motors, measurements are commonly taken near the bearing locations.
Typical points include:
Drive End — DE
and:
Non-Drive End — NDE
Measurements may be taken in:
Horizontal
Vertical
Axial
For condition monitoring, repeat the measurement at the same point whenever practical.
Example Measurement Point
Instead of writing:
Motor vibration = 2.4 mm/s
record:
Motor 03 — DE — Horizontal — 2.4 mm/s RMS
This gives much more useful information.
Next month, the technician knows exactly where to measure again.
How to Read a Motor Vibration Trend
Consider the following readings from the same motor point:
January — 1.7 mm/s
February — 1.8 mm/s
March — 1.8 mm/s
April — 2.0 mm/s
May — 2.6 mm/s
June — 3.4 mm/s
The most important feature is the trend.
The vibration has increased significantly compared with the historical baseline.
Maintenance personnel can now investigate possible causes.
What Can Cause the Reading to Increase?
Possible causes include:
Bearing deterioration
Rotor imbalance
Misalignment
Mechanical looseness
Soft foot
Coupling problems
Foundation problems
Problems from the driven machine
A vibration meter tells you that machine behaviour has changed.
It does not automatically identify which fault is responsible.
How to Read Pump Vibration
For a motor-driven pump, do not take only one reading.
A practical route may include:
Motor NDE → Motor DE → Pump DE → Pump NDE
Suppose readings are:
Motor NDE — 1.8 mm/s
Motor DE — 2.0 mm/s
Pump DE — 4.2 mm/s
Pump NDE — 4.0 mm/s
The higher pump-side measurements provide useful troubleshooting information.
Possible investigation areas include:
Pump bearings
Impeller
Cavitation
Pump mounting
Alignment
How to Read Fan Vibration
For a fan system, compare measurements across:
Motor → Drive System → Fan Bearings
Increasing vibration may relate to:
Fan imbalance
Dirty blades
Bearing wear
Belt problems
Pulley misalignment
Loose mounting
Historical readings help determine whether the fan condition is changing.
Why RPM Matters
Vibration behaviour depends partly on rotational speed.
If a variable-speed motor measures:
1.8 mm/s at 800 RPM
and:
3.0 mm/s at 1,500 RPM
you should not compare the two readings without considering the speed difference.
For useful trending, measure under similar operating conditions whenever possible.
Why Load Matters
Machine load can also influence vibration.
A pump at low flow may behave differently from the same pump at its normal duty point.
A compressor under light load may behave differently from one operating under full production conditions.
Record operating conditions where practical.
What Is a Good Vibration Reading?
There is no single number that represents a good vibration reading for every machine.
Evaluation depends on:
Machine type
Machine size
Speed
Mounting
Foundation
Measurement location
Operating load
Manufacturer recommendations
Applicable standards
Historical baseline measurements are also extremely useful.
Should I Use an Online Vibration Chart?
Online charts can be useful for general learning, but technicians should be careful about applying a generic chart to every machine.
Before using any vibration limit, confirm:
Which standard it is based on
Which machine category applies
Which measurement parameter is used
Which measurement method is required
For industrial machinery, applicable standards such as the relevant ISO 20816 series may be considered depending on the machine and application.
Always use the appropriate current criteria for the equipment being evaluated.
What If the Reading Suddenly Doubles?
A sudden significant change deserves attention.
For example:
Previous reading:
1.9 mm/s
Current reading:
4.1 mm/s
Before assuming the machine is damaged:
Repeat the measurement.
Confirm the same measurement point.
Confirm the same parameter.
Check machine speed and load.
Inspect the sensor contact.
Check for obvious mechanical changes.
If the higher reading is confirmed, investigate the machine.
What If the Reading Slowly Increases?
Gradual increase is exactly why condition monitoring is valuable.
For example:
1.5 → 1.6 → 1.8 → 2.1 → 2.7 → 3.4 mm/s
This may indicate developing mechanical deterioration.
Maintenance can investigate before the machine reaches an obvious failure condition.
Record Your Vibration Readings
A basic record can contain:
Date | Machine | Point | Direction | Velocity | RPM | Load | Remarks
You can start with a spreadsheet or existing maintenance system.
The important thing is to create consistent historical information.
Vibration Meter Options from MTM Precision Malaysia
MTM Precision supplies portable vibration meters for industrial maintenance and machine condition monitoring.
Showa Sokki SH-1332B
Suitable for professional industrial vibration measurement and maintenance applications.
Landtek VM6310 / VM6360 / VM6380
Portable vibration meter options for different machinery vibration measurement requirements.
Wintact Vibration Meters
Suitable for routine motor, pump, fan, bearing and machinery vibration checks.
Benetech Vibration Meters
Additional portable options for general industrial vibration measurement and maintenance applications.
Different models offer different measurement parameters and capabilities.
The Most Important Rule
Do not use a vibration meter only to ask:
“Is 3 mm/s good or bad?”
Instead ask:
What machine?
Which measurement point?
Which parameter?
What operating condition?
What was the previous reading?
What limit applies?
This turns a simple number into useful maintenance information.
Looking for a Vibration Meter in Malaysia?
MTM Precision Sdn Bhd supplies vibration meters and industrial testing instruments for factory maintenance, engineering, HVAC, facility management and machine condition monitoring applications in Malaysia.
Applications include:
Electric Motor → Bearing → Pump → Fan → Compressor → Gearbox → Generator → HVAC → Factory Machinery
If you are unsure how to select a suitable vibration meter or which vibration parameters you require, contact MTM Precision with your machine application.
MTM Precision Sdn Bhd
Website: www.mtmpre.com.my
WhatsApp: +6016-660 7346
Email: mtmpre@yahoo.com
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
20 Aug 2026