How to Measure Color Difference with Linshang LS173 Colorimeter Malaysia

How to Measure Color Difference with Linshang LS173 Colorimeter Malaysia

 

When two products appear to be almost the same color, how can a quality control team determine whether the difference is acceptable?

 

Visual inspection alone may not provide a consistent answer. Lighting conditions, operator experience and individual color perception can all influence the result.

 

The Linshang LS173 D/8 Touch Screen Colorimeter provides a practical method for comparing a standard sample with a test sample using measurable color data and Delta E (ΔE) color difference values.

 

For manufacturers in Malaysia, this can help turn subjective color judgement into a more repeatable quality control process.

 

What Does Color Difference Measurement Mean?

 

Color difference measurement compares the color of one sample against another.

 

Normally, one sample is selected as the standard or reference, while the second sample is the product being inspected.

 

For example:

 

Approved Master Sample → Standard

 

Current Production Sample → Test Sample

 

The instrument measures both samples and calculates their color difference.

 

This allows QC personnel to evaluate the difference using numerical information rather than relying only on statements such as:

 

“It looks slightly darker.”

 

“This batch seems more yellow.”

 

“The colors are almost the same.”

 

“I think this is acceptable.”

 

Step 1: Select an Approved Standard Sample

 

The first step is to establish a suitable reference.

 

Depending on the application, this may be:

 

Customer-approved sample

 

Master color sample

 

Approved production part

 

Reference plastic component

 

Standard painted panel

 

Approved printed sample

 

Packaging master sample

 

The quality of the reference is important because future production samples will be compared against it.

 

Companies should therefore protect and manage their master samples carefully.

 

Step 2: Prepare the Measurement Area

 

Before measurement, ensure that the sample and measurement area are suitable for inspection.

 

The surface should be representative of the product being evaluated.

 

For repeatable QC, operators should try to measure samples in a consistent manner.

 

Depending on the application, companies may establish a fixed measurement location on each product.

 

For example, instead of measuring random positions on a plastic housing, the QC procedure may specify one particular flat area for every inspection.

 

Consistency in measurement procedure helps improve consistency in results.

 

Step 3: Measure the Standard

 

Use the Linshang LS173 to measure the approved reference sample.

 

This establishes the color information that will be used for comparison.

 

In routine manufacturing QC, this reference may represent the target color for subsequent production.

 

The same approved reference can then be used when checking:

 

Incoming materials

 

First-off production samples

 

In-process samples

 

Finished products

 

New supplier samples

 

Repeat production batches

 

Step 4: Measure the Test Sample

 

Next, measure the product that needs to be inspected.

 

For example, this could be a component taken from the latest production batch.

 

The LS173 can then provide measurement data that can be compared with the established reference.

 

This process can be repeated across multiple samples to evaluate production consistency.

 

Step 5: Review Delta E

 

One of the important values in color comparison is Delta E (ΔE).

 

Delta E represents the measured difference between two colors.

 

As a general concept:

 

Small ΔE → smaller color difference

 

Large ΔE → greater color difference

 

However, this does not mean that every company should use the same Delta E acceptance limit.

 

The acceptable tolerance depends on factors such as:

 

Customer specification

 

Product type

 

Material

 

Industry

 

Surface appearance

 

Quality requirements

 

Application

 

Companies should establish acceptance criteria appropriate to their own products.

 

Step 6: Accept, Reject or Investigate

 

Once the measurement has been compared with the company's established QC criteria, the sample can be evaluated.

 

A simple workflow may be:

 

Measure → Compare → Within Tolerance?

 

YES → Accept

 

NO → Investigate / Hold / Reject According to QC Procedure

 

This provides a clearer decision-making process than visual inspection alone.

 

Example: Plastic Injection Molding

 

Consider a plastic injection molding company producing black equipment housings.

 

The customer has already approved one master sample.

 

A new production batch is started.

 

The QC team can:

 

Measure the approved master.

 

Measure the first production sample.

 

Compare the color difference.

 

Continue production if the sample meets established requirements.

 

Measure additional samples periodically.

 

Investigate if the color begins moving outside the defined tolerance.

 

This approach can help detect changes before thousands of components are produced.

 

Example: Paint and Coating

 

A metal fabrication company produces painted equipment enclosures.

 

The customer requires each batch to maintain a consistent appearance.

 

Instead of simply comparing the new enclosure visually with an older one, the QC department can use the LS173 to measure both samples.

 

The resulting color data provides an additional objective reference for the inspection decision.

 

Example: Printing and Packaging

 

A manufacturer orders printed packaging every few months.

 

When a new shipment arrives, the packaging looks slightly different from the previous approved batch.

 

Is the difference real?

 

Is it caused by lighting?

 

Is the new printing actually outside the company's tolerance?

 

Color measurement provides a more objective method for investigating the issue.

 

The approved packaging sample can be used as the standard and the new batch measured as the test sample.

 

Why D/8 Geometry Matters

 

The Linshang LS173 uses D/8 optical geometry, referring to diffuse illumination with an 8-degree viewing geometry.

 

Controlled measurement geometry is important because instrumental color measurement should be performed under defined optical conditions.

 

This helps companies establish a more standardized and repeatable approach to color inspection.

 

Avoid These Common Color Measurement Mistakes

 

Even with a colorimeter, measurement procedures matter.

 

Companies should avoid inconsistent practices such as:

 

Measuring different locations every time

 

Using damaged or contaminated reference samples

 

Comparing unrelated materials

 

Changing the inspection procedure between operators

 

Using an arbitrary Delta E tolerance without considering the application

 

Depending on only one measurement when the product surface is highly variable

 

A good instrument should be supported by a good QC procedure.

 

Should You Measure More Than One Point?

 

For products with possible surface or color variation, measuring several representative points may provide more useful information than relying on a single measurement.

 

The appropriate procedure depends on the product.

 

A QC team may establish:

 

Point A + Point B + Point C → Review Overall Consistency

 

The important point is to create a repeatable procedure that operators can follow consistently.

 

Colorimeter vs Human Eye

 

A colorimeter should not necessarily replace visual inspection.

 

The two methods can complement each other.

 

Visual Inspection

 

Useful for evaluating overall appearance, obvious defects and how the finished product looks to the customer.

 

Instrumental Color Measurement

 

Useful for obtaining objective numerical color data and comparing samples consistently.

 

For many manufacturers, combining both approaches creates a stronger QC process.

 

Where Can the Linshang LS173 Be Used?

 

The LS173 may be considered for color measurement applications involving suitable:

 

Plastic products

 

Painted components

 

Coated surfaces

 

Printed materials

 

Packaging

 

Labels

 

Consumer products

 

Manufactured components

 

Potential users include QA/QC departments, production teams, supplier quality engineers, purchasing departments and R&D personnel.

 

Building a Color Measurement SOP

 

For companies that perform frequent color inspections, it is useful to establish an internal Standard Operating Procedure.

 

The SOP can define:

 

Approved reference sample

 

Measurement location

 

Number of measurements

 

Color difference parameter

 

Acceptance tolerance

 

Inspection frequency

 

Record keeping

 

Action for non-conforming samples

 

This helps ensure that different operators follow the same inspection method.

 

From Opinion to Measurement

 

Without instrumental measurement:

 

QC: “This batch looks different.”

 

Production: “It looks the same to us.”

 

Supplier: “We cannot see any difference.”

 

With an established color measurement procedure, the discussion can move toward measurable data.

 

That is one of the main benefits of introducing a colorimeter into industrial quality control.

 

Linshang LS173 Color Difference Meter Malaysia

 

MTM Precision supplies industrial testing and measurement instruments for manufacturing and quality control applications throughout Malaysia.

 

If your company needs to measure color difference, Delta E, batch consistency or product color quality, the Linshang LS173 can be considered for suitable applications.

 

Contact MTM Precision with information about your sample and measurement requirements so our team can assist you with product selection.

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd.

 

Showroom & Service Centre

 

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia

 

🌐 Website: www.mtmpre.com.my

📧 Email: mtmpre@yahoo.com

📱 WhatsApp: +6016-660 7346

 

Need a Linshang LS173 for color difference and Delta E measurement in Malaysia? Contact MTM Precision for quotation and application enquiries.


 

12 Aug 2026