Linshang LS173 Portable Colorimeter for Incoming Quality Control IQC Malaysia
Linshang LS173 Portable Colorimeter for Incoming Quality Control IQC Malaysia
Incoming materials can pass dimensional inspection and still create production problems because of color variation. Plastic parts, painted components, printed packaging and other colored materials supplied in different batches may not always match the approved standard.
The Linshang LS173 Portable Colorimeter can support Incoming Quality Control (IQC) by providing objective color measurement and color difference comparison before incoming materials are released to production.
For manufacturers in Malaysia, this can help identify potential color problems earlier and reduce the risk of using non-conforming materials.
Why Check Color During Incoming Inspection?
Many manufacturers purchase colored materials or finished components from external suppliers.
Examples include:
Plastic injection-molded parts
Painted components
Coated products
Printed cartons
Packaging
Labels
Consumer product components
Other colored manufactured parts
Even when the supplier follows the same specification, differences can occur between deliveries.
If these differences are discovered only after assembly or production, correcting the problem can become more expensive.
A Typical Incoming Color Problem
Consider a company purchasing blue plastic housings from a supplier.
The first shipment is approved.
Three months later, another shipment arrives.
The new components look slightly different.
The supplier says:
“It is the same color code.”
Production says:
“It should be okay.”
QC says:
“The new batch looks darker.”
Who is correct?
Without objective measurement, the discussion may depend heavily on personal judgement.
A colorimeter provides additional numerical information for evaluating the difference.
Establish an Approved Master Sample
A good incoming color inspection procedure begins with an approved reference.
This may be:
Customer-approved sample
Golden sample
Master plastic component
Standard painted panel
Approved packaging sample
Reference printed sample
Previously approved production part
Incoming samples can then be compared against the same controlled reference.
This is generally more consistent than comparing each new delivery only with the previous shipment.
How to Use the LS173 for IQC
A simple incoming inspection workflow can be:
Step 1: Receive Supplier Shipment
Select representative samples according to your company's inspection procedure.
Step 2: Visual Inspection
Check general appearance, surface condition and obvious defects.
Step 3: Measure the Approved Standard
Use the LS173 according to the established measurement procedure.
Step 4: Measure Incoming Samples
Measure the defined area of the incoming product.
Step 5: Compare Color Difference
Review the measured results and Delta E where applicable.
Step 6: Make the IQC Decision
Accept, hold, investigate or reject according to the company's established requirements.
Delta E for Incoming Inspection
Delta E (ΔE) is commonly used to express the measured difference between two colors.
In general:
Lower ΔE = smaller measured difference
Higher ΔE = greater measured difference
This can be useful when comparing an incoming component against an approved master.
However, companies should establish suitable acceptance criteria for their own applications.
The correct tolerance may depend on:
Customer requirements
Material
Product type
Appearance requirements
Manufacturing process
Internal quality standards
A single universal Delta E pass/fail limit should not be applied automatically to every product.
Incoming Plastic Component Inspection
Plastic parts are a good example of where color measurement can support IQC.
Variation may result from:
Resin batches
Masterbatch
Pigments
Processing parameters
Supplier production conditions
Material formulation
If several suppliers produce the same component, color consistency may become even more difficult to control.
Using the same approved master sample provides a common reference for supplier comparison.
Incoming Painted Component Inspection
Companies that outsource painting or coating can also experience color variation.
A component may have the correct dimensions and coating coverage but still fail the required appearance.
Suitable painted samples can be measured against an approved reference before they are released for assembly or further processing.
Depending on the specification, separate instruments may also be required to check gloss and coating thickness.
Incoming Packaging Inspection
Packaging color can be especially important for branded consumer products.
A new shipment of cartons or labels may be technically usable but visually inconsistent with previous approved production.
For suitable packaging materials, the LS173 can support incoming color comparison before the materials are used for packing finished products.
This may help prevent situations where different packaging shades appear together in the market.
Supplier A vs Supplier B
Manufacturers often need more than one supplier for the same component.
For example:
Approved Master
↓
Supplier A Sample
↓
Supplier B Sample
↓
Supplier C Sample
Each supplier can be evaluated against the same master rather than against one another.
This creates a more standardized approach to supplier quality control.
Why Visual Inspection Alone May Not Be Enough
Visual inspection is still important, but it can be influenced by:
Lighting conditions
Operator experience
Background color
Viewing angle
Eye fatigue
Individual perception
A sample accepted by one inspector may be questioned by another.
Instrumental color measurement helps reduce this subjectivity by providing numerical data to support the decision.
D/8 Measurement Geometry
The Linshang LS173 uses D/8 optical geometry, referring to diffuse illumination with an 8-degree viewing geometry.
Controlled measurement conditions help provide more repeatable color evaluation than uncontrolled visual comparison alone.
For IQC departments, repeatability is particularly important because incoming inspections may be performed by different operators over long periods.
Why Portability Is Useful for IQC
Incoming inspection does not always take place in a laboratory.
Materials may need to be checked at:
Receiving areas
Warehouses
QC departments
Production areas
Supplier sites
A portable colorimeter allows measurement to be performed closer to the material being inspected.
This can make it easier to incorporate color measurement into routine incoming inspection.
Reduce the Cost of Detecting Problems Too Late
Imagine that an incorrect-color component is accepted during incoming inspection.
It then goes through:
Receiving → Storage → Production → Assembly → Packing → Final Inspection
Only at the final stage does someone notice that the color does not match.
By this point, the company may already have invested labor and production time into the affected products.
Identifying the problem at the incoming stage can therefore be much less costly.
Improve Supplier Communication
Objective measurement can also make supplier discussions more productive.
Instead of saying:
“Your latest batch looks different.”
the QC team can discuss measured color difference data based on an agreed inspection method.
This does not automatically eliminate supplier disputes, but it provides a stronger technical basis for investigation.
Create an Incoming Color Inspection SOP
Companies performing regular color inspection should consider establishing a documented procedure.
The SOP can define:
Approved master sample
Sampling quantity
Measurement location
Number of measurements
Color parameters
Acceptance tolerance
Measurement method
Record keeping
Action for non-conforming materials
The LS173 then becomes part of a controlled QC system rather than simply a standalone measuring device.
Who Can Use the LS173 for IQC?
Potential users include:
Incoming QC inspectors
QA departments
Supplier quality engineers
Purchasing departments
Production engineers
Plastic manufacturers
Paint and coating companies
Packaging manufacturers
Printing companies
General manufacturing companies
It is especially useful where incoming product color needs to be compared consistently against an approved reference.
From Incoming Inspection to Final Quality
Good finished-product quality often begins with good incoming material control.
If incorrect or inconsistent materials enter production, problems become harder and more expensive to correct later.
Adding objective color measurement to IQC can therefore support the wider quality management process.
Linshang LS173 for Incoming Quality Control Malaysia
MTM Precision supplies industrial testing and measurement instruments for manufacturing, engineering and quality control applications throughout Malaysia.
If your company needs a portable colorimeter for incoming inspection, supplier color comparison, Delta E measurement or batch color consistency, contact MTM Precision to discuss your application.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
🌐 Website: www.mtmpre.com.my
📧 Email: mtmpre@yahoo.com
📱 WhatsApp: +6016-660 7346
Looking for a Linshang LS173 Portable Colorimeter for Incoming Quality Control in Malaysia? Contact MTM Precision for quotation, product information and application enquiries.
12 Aug 2026