How to Check the Best Solar Panel Angle Using a Solar Power Meter Malaysia
How to Check the Best Solar Panel Angle Using a Solar Power Meter Malaysia
Solar panel angle can influence how much solar radiation reaches the surface of a photovoltaic module. Even when two panels are installed at the same location, differences in tilt and orientation can result in different levels of solar exposure.
A portable instrument such as the TENMARS TM-206A Solar Power Meter can be used to compare solar irradiance at different angles, providing useful field information for solar PV installers, technicians and engineers in Malaysia.
Why Does Solar Panel Angle Matter?
Solar panels generate electricity from sunlight reaching the photovoltaic modules.
The amount of solar radiation received depends partly on the relationship between:
Sun position
Panel orientation
Panel tilt angle
Time of day
Season
Surrounding shading
Weather conditions
A panel positioned more favourably toward incoming sunlight may receive higher irradiance than another panel at a less suitable angle.
This is why panel orientation and tilt are important considerations during solar PV installation.
What Does a Solar Power Meter Measure?
The TENMARS TM-206A measures solar radiation reaching its sensor.
Solar irradiance can be displayed in:
W/m² — watts per square metre
The TM-206A has a measurement range up to 1999 W/m², making it suitable for outdoor solar radiation measurements.
Instead of judging sunlight intensity visually, technicians can obtain numerical readings for comparison.
How to Compare Different Solar Panel Angles
A simple field comparison can be performed using the TM-206A.
Step 1: Choose the Test Location
Perform the measurements near the proposed solar panel installation area.
Make sure there are no unexpected shadows from:
Buildings
Trees
Roof structures
Antennas
Water tanks
The technician performing the measurement
Step 2: Position the Solar Power Meter
Orient the sensing surface to represent the proposed plane of the solar panel.
The orientation of the sensor should be controlled carefully because changing the angle can change the measured irradiance.
Step 3: Record the First Reading
Take a solar irradiance measurement at the first proposed angle.
For example:
Angle A: 760 W/m²
Record the result.
Step 4: Change the Angle
Adjust the sensor to represent another proposed panel position.
For example:
Angle B: 835 W/m²
Step 5: Compare Additional Positions
Continue with another angle if required.
For example:
Angle C: 905 W/m²
Under the conditions at that particular moment:
Angle A = 760 W/m²
Angle B = 835 W/m²
Angle C = 905 W/m²
Angle C receives the strongest solar irradiance during this specific comparison.
One Measurement Is Not Enough for System Design
An important point is that the sun's position changes throughout the day and throughout the year.
The angle producing the highest reading at noon on one particular day is not automatically the best year-round solar panel angle.
Professional PV system design should also consider:
Geographic location
Roof direction
Seasonal solar path
Morning and afternoon exposure
Shading throughout the day
Structural limitations
Drainage and maintenance access
Long-term energy production requirements
The TM-206A should therefore be used as a field measurement and comparison tool, rather than as the only basis for PV system design.
Compare Measurements Under Similar Conditions
Malaysia's weather can change quickly.
If Angle A is measured under clear sunlight but Angle B is measured just as a cloud passes overhead, the comparison will not be meaningful.
For better results:
Take readings close together in time
Avoid rapidly changing weather where possible
Repeat measurements
Maintain consistent test procedures
Record weather conditions
Avoid accidental sensor shading
This improves the reliability of the comparison.
Finding Areas with Better Solar Exposure
The same method can be used to compare different roof locations.
For example:
Roof Area A: 880 W/m²
Roof Area B: 720 W/m²
Roof Area C: 895 W/m²
The lower reading at Area B may indicate shading or a less favourable orientation at the time of measurement.
Further inspection can then determine the reason.
Useful for Existing Solar PV Systems
Solar power meters are not only useful before installation.
Technicians maintaining existing systems can use irradiance measurements when investigating:
Unexpectedly low PV output
New shading conditions
Changes caused by nearby construction
Vegetation growth
Differences between panel arrays
Performance complaints
If a solar array receives strong irradiance but produces unusually low output, the technician can investigate the electrical system and PV modules further.
Solar Irradiance vs PV Output
It is important to understand that solar irradiance and electrical output are different measurements.
Solar Power Meter
Measures the solar radiation reaching the measurement surface.
PV Electrical Test Equipment
Measures electrical parameters produced by the solar PV system.
Using both types of information provides a more complete understanding of system conditions.
Who Can Use the TENMARS TM-206A?
The TM-206A is suitable for:
Solar PV installers
Solar maintenance contractors
Electrical contractors
Energy consultants
Facility management teams
Engineering companies
Universities
Technical colleges
Building maintenance departments
Its handheld design makes it convenient for field comparison and routine solar radiation measurement.
Solar Power Meter Supplier in Malaysia
For professionals who need a portable instrument to measure solar radiation or compare solar exposure at different positions, the TENMARS TM-206A Solar Power Meter provides a practical solution.
MTM Precision supplies professional solar, electrical, environmental and industrial testing equipment in Malaysia.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
🌐 Website: www.mtmpre.com.my
📧 Email: mtmpre@yahoo.com
📱 WhatsApp: +6016-660 7346
15 Aug 2026