TENMARS TM-206A for Window Tint and Solar Film Testing Malaysia
TENMARS TM-206A for Window Tint and Solar Film Testing Malaysia
Window tint and solar control film are commonly used in Malaysia to reduce the amount of solar energy entering vehicles and buildings. While visible darkness can be judged by eye, appearance alone does not show how much solar radiation is actually transmitted through the glass.
The TENMARS TM-206A Solar Power Meter can be used to compare solar radiation before and after sunlight passes through glass or solar film, making it useful for practical solar transmission comparison.
Why Test Window Tint and Solar Film?
Malaysia experiences strong sunlight and high temperatures throughout the year.
Solar film is commonly installed on:
Car windows
Office buildings
Shoplots
Residential properties
Commercial buildings
Factory offices
Glass façades
Customers often want to know whether a film actually reduces solar energy transmission.
A solar power meter provides a simple way to demonstrate the difference using actual measurements.
What Does the TENMARS TM-206A Measure?
The TM-206A measures solar radiation intensity.
Its measurement range extends up to:
1999 W/m²
Measurements can be displayed in:
W/m²
BTU/(ft²·h)
For window tint and solar film applications, users can compare solar radiation on the outside of the glass with the amount transmitted through the glass or film.
How to Test Window Tint with TM-206A
A basic comparative test can be performed in several steps.
Step 1: Measure Direct Solar Radiation
Position the TM-206A sensor where it receives direct sunlight.
For example:
Direct sunlight: 900 W/m²
Record the reading.
Step 2: Measure Behind the Glass
Place the sensor behind the window glass while maintaining a consistent measurement position.
For example:
Behind untreated glass: 650 W/m²
Step 3: Measure Behind Solar Film
Repeat the measurement after solar film is applied, or compare another piece of glass fitted with film.
For example:
Behind solar film: 280 W/m²
This demonstrates that less solar radiation reaches the sensor after passing through the film under those test conditions.
Simple Solar Transmission Comparison
The readings can also be used for a basic comparison.
For example:
Direct sunlight = 900 W/m²
After solar film = 270 W/m²
Approximate transmitted solar radiation:
270 ÷ 900 × 100 = 30%
This indicates that approximately 30% of the measured solar radiation reached the sensor through the tested material under those particular conditions.
This should be treated as a practical field comparison rather than a replacement for laboratory-certified optical or solar-performance testing.
Useful for Automotive Tint Shops
For automotive window tint businesses, the TM-206A can provide a useful demonstration tool.
Instead of telling customers only:
“This film reduces solar heat.”
The shop can demonstrate measurable differences between:
Untinted glass
Standard tint
Premium solar film
Different film models
This makes the explanation more visual and measurable.
Darker Tint Does Not Always Mean Better Solar Performance
A common misconception is that darker film automatically provides better solar heat reduction.
Visible darkness and solar energy transmission are not exactly the same property.
Two films with similar appearance may perform differently depending on their construction and materials.
Therefore, objective measurement can provide additional information when comparing products.
Building Glass Applications
The same measurement principle can be applied to buildings.
Potential applications include:
Office window film
Residential window tint
Shopfront glass
Factory office windows
Commercial building glass
Solar control glazing
Glass façade comparison
Facility managers and building contractors can compare solar radiation at different windows or before and after solar film installation.
Before-and-After Testing
One particularly useful application is documenting conditions before and after installation.
For example:
Before Solar Film Installation
Solar radiation behind glass: 620 W/m²
After Solar Film Installation
Solar radiation behind glass: 250 W/m²
This provides the customer with a straightforward numerical comparison.
Keep Test Conditions Consistent
Solar radiation changes continuously because of:
Cloud movement
Time of day
Sun angle
Weather
Sensor orientation
For better comparisons:
Take readings close together in time
Keep the sensor in the same position
Maintain the same sensor angle
Avoid shadows
Repeat the measurement
Record weather conditions when necessary
Consistent testing procedures are important when comparing different films.
Solar Power Meter vs Light Meter
A solar power meter and a lux meter are not the same instrument.
A lux meter measures visible illuminance.
A solar power meter measures solar radiation intensity.
Therefore, a solar power meter is more relevant when the objective is to compare solar energy reaching the sensor rather than simply measuring visible brightness.
Who Can Use the TM-206A?
The TENMARS TM-206A can be useful for:
Automotive tint shops
Solar film installers
Building contractors
Glass suppliers
Facility management teams
Property maintenance companies
Solar PV installers
Engineering companies
Technical laboratories
This versatility means one instrument can support both solar PV and solar transmission applications.
TENMARS TM-206A Supplier Malaysia
The TENMARS TM-206A Solar Power Meter provides a practical solution for solar radiation measurements involving photovoltaic systems, glass, window tint and solar control film.
MTM Precision supplies professional testing and measurement instruments for solar, environmental, electrical, building and industrial applications in Malaysia.
Contact us if you need assistance selecting a suitable instrument for your solar radiation or solar film testing application.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia
🌐 Website: www.mtmpre.com.my
📧 Email: mtmpre@yahoo.com
📱 WhatsApp: +6016-660 7346
15 Aug 2026