TENMARS TM-206A Solar Power Meter Troubleshooting and Measurement Tips Malaysia

TENMARS TM-206A Solar Power Meter Troubleshooting and Measurement Tips Malaysia

 

Accurate solar radiation measurement depends not only on the instrument but also on how the measurement is performed. Sensor orientation, shadows, cloud movement and changing sunlight conditions can all affect readings.

 

The TENMARS TM-206A Solar Power Meter is designed for portable solar radiation measurement and can be used for solar PV, building glass, automotive window tint and solar film applications.

 

If readings appear inconsistent, the following practical checks can help identify common measurement problems.

 

1. Solar Reading Changes Very Quickly

 

Rapidly changing readings do not necessarily indicate a faulty meter.

 

Outdoor solar radiation can change within seconds because of:

 

Moving clouds

 

Partial cloud cover

 

Changing sensor angle

 

Shadows

 

Movement of the instrument

 

This is especially relevant under Malaysia's tropical weather conditions.

 

What to Do

 

Keep the meter in a stable position and observe the reading.

 

If clouds are moving across the sun, wait for more consistent conditions before comparing different locations or materials.

 

2. Reading Changes When the Meter Is Tilted

 

This can be normal.

 

Solar radiation reaching a surface depends partly on its orientation relative to the sun.

 

If the sensor is tilted in different directions, the measured irradiance can change.

 

What to Do

 

When comparing measurements, maintain a consistent sensor orientation.

 

For solar PV testing, position the sensing surface to represent the plane of the solar panel as closely as practical.

 

3. Reading Is Lower Than Expected

 

Several factors can cause a lower solar irradiance reading.

 

Check for:

 

Cloud cover

 

Partial shading

 

Nearby buildings

 

Trees

 

Roof structures

 

Incorrect sensor orientation

 

Obstruction over the sensor

 

Do not assume immediately that the meter has a problem.

 

Compare the reading in a fully exposed location under stable sunlight.

 

4. Different Roof Areas Give Different Results

 

This may be exactly what the measurement is showing.

 

Two roof areas can receive different levels of solar radiation because of orientation or shading.

 

For example:

 

Roof A: 880 W/m虏

Roof B: 730 W/m虏

 

Before concluding that Roof B is unsuitable, investigate the reason for the difference.

 

The result may be influenced by the sun's position at the time of testing.

 

5. Results Are Different at Different Times of Day

 

This is expected.

 

The sun's position changes throughout the day, so irradiance at a particular surface also changes.

 

A measurement taken at 9:00 AM should not automatically be compared directly with one taken at 1:00 PM.

 

For meaningful comparisons, record:

 

Time

 

Location

 

Sensor orientation

 

Weather conditions

 

Irradiance reading

 

6. Window Tint Test Results Are Inconsistent

 

When testing automotive tint or building solar film, changing sunlight can make before-and-after comparisons misleading.

 

For example:

 

Direct sunlight measurement: 900 W/m虏

 

A cloud then moves overhead.

 

Film measurement: 250 W/m虏

 

The apparent reduction cannot be attributed entirely to the film because the incoming solar radiation also changed.

 

Better Method

 

Perform the measurements as close together in time as possible and repeat the test.

 

Keep the sensor position and angle consistent.

 

7. Do Not Accidentally Shade the Sensor

 

This is one of the simplest measurement mistakes.

 

The technician's:

 

Body

 

Hand

 

Head

 

Tool

 

Clipboard

 

may partially block sunlight reaching the sensor.

 

Even a small shadow can affect the reading.

 

Always check the sensor before recording a measurement.

 

8. Keep the Sensor Surface Clean

 

Dust, dirt or contamination on the sensing area may interfere with measurement.

 

For field instruments used at construction sites, factories or rooftops, regularly inspect the sensor.

 

Follow the manufacturer's care and cleaning recommendations and avoid damaging the sensing surface.

 

9. Repeat Measurements

 

Do not rely unnecessarily on one instantaneous reading.

 

For important comparisons, take several readings under similar conditions.

 

For example:

 

Reading 1: 865 W/m虏

Reading 2: 872 W/m虏

Reading 3: 868 W/m虏

 

Repeated measurements can provide greater confidence that the observed value represents the current conditions.

 

10. Solar Irradiance Does Not Equal PV Electrical Output

 

This is an important troubleshooting point.

 

The TM-206A measures solar radiation.

 

It does not directly measure the electrical performance of a PV system.

 

A solar panel receiving strong irradiance can still produce abnormal electrical output because of:

 

Module problems

 

Wiring faults

 

Connector issues

 

Inverter problems

 

Dirt

 

Partial shading

 

System configuration

 

Solar irradiance measurement provides environmental context for PV troubleshooting.

 

11. Solar Power Meter Is Not a Lux Meter

 

A lux meter measures visible illuminance.

 

The TENMARS TM-206A measures solar radiation.

 

The two measurements should not be treated as interchangeable.

 

If your application specifically requires solar irradiance in W/m虏, use an appropriate solar radiation instrument.

 

12. Solar Power Meter Is Not a VLT Meter

 

For automotive window tint applications, remember that solar radiation measurement and Visible Light Transmission are different.

 

A dedicated tint or VLT meter is required when the objective is to measure visible-light transmission.

 

The TM-206A is useful when comparing solar radiation before and after sunlight passes through glass or solar film.

 

Tips for More Consistent Solar Measurements

 

For better field measurements:

 

Avoid accidental sensor shading

 

Maintain consistent sensor orientation

 

Record the measurement time

 

Note weather conditions

 

Take comparison readings close together

 

Repeat measurements when necessary

 

Keep the sensor clean

 

Use the correct instrument for the required parameter

 

Good measurement practice is just as important as selecting the right meter.

 

Applications for TENMARS TM-206A

 

The TM-206A can support several types of work:

 

Solar PV installation

 

Solar PV maintenance

 

Solar irradiance measurement

 

Panel angle comparison

 

Shading investigation

 

Automotive glass testing

 

Window tint comparison

 

Building solar film assessment

 

This makes it useful for solar contractors as well as companies working with glass and solar control products.

 

Who Can Use the TENMARS TM-206A?

 

Typical users include:

 

Solar PV installers

 

Electrical contractors

 

Solar maintenance technicians

 

Energy consultants

 

Facility management teams

 

Automotive tint shops

 

Solar film installers

 

Building contractors

 

Engineering companies

 

Universities and technical institutions

 

TENMARS TM-206A Supplier Malaysia

 

For users looking for a portable instrument for solar radiation measurement, the TENMARS TM-206A Solar Power Meter provides a practical solution for field testing and comparative measurements.

 

MTM Precision supplies professional solar, electrical, environmental and industrial testing instruments in Malaysia.

 

Contact us for assistance selecting suitable solar testing equipment for your application.

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd.

Showroom & Service Centre

 

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia

 

🌐 Website: www.mtmpre.com.my

📧 Email: mtmpre@yahoo.com

📱 WhatsApp: +6016-660 7346


 

15 Aug 2026