How to Measure Solar Irradiance Using TENMARS TM-207 Malaysia

How to Measure Solar Irradiance Using TENMARS TM-207 Malaysia

 

Solar irradiance measurement helps users understand how much solar radiation is reaching a particular surface or location. For solar PV contractors, engineers and building professionals, actual field measurements can provide useful information that cannot be obtained simply by looking at the sunlight conditions.

 

The TENMARS TM-207 Solar Power Meter is a portable instrument designed for quick solar radiation measurement in applications such as solar PV assessment, building inspection, glass testing and solar film evaluation.

 

What Does Solar Irradiance Mean?

 

Solar irradiance describes the amount of solar power received over a specific surface area.

 

It is commonly expressed in:

 

W/m² — watts per square metre

 

For example, two areas may appear equally sunny to the human eye but produce different irradiance readings because of orientation, cloud conditions, shading or surrounding structures.

 

This is why measurement is useful when evaluating solar energy conditions.

 

TENMARS TM-207 Measurement Range

 

The TENMARS TM-207 measures solar radiation up to:

 

1999 W/m²

 

It can display measurements in:

 

W/m²

 

BTU/(ft²·h)

 

Its spectral response is approximately 400–1100 nm.

 

The handheld design makes it convenient for technicians who need to take measurements at multiple locations around a site.

 

Step 1: Select the Measurement Location

 

Start by identifying the area you want to evaluate.

 

For solar PV applications, this could include:

 

Factory rooftop

 

Residential roof

 

Commercial building

 

Warehouse

 

Open field

 

Car park

 

Existing solar PV installation

 

Avoid taking only one measurement.

 

If possible, compare several locations around the proposed installation area.

 

Step 2: Position the Sensor

 

Position the solar sensor so that it receives the sunlight you want to measure.

 

The sensor orientation is important because changing the angle relative to the sun can change the measured solar radiation.

 

If you are comparing several positions, try to maintain consistent measurement conditions.

 

Step 3: Read the Solar Irradiance

 

Observe the reading displayed by the TM-207.

 

For solar applications, W/m² is generally the most useful unit.

 

Record the measurement together with relevant information such as:

 

Time

 

Location

 

Weather

 

Sensor angle

 

Shading condition

 

This makes later comparisons more meaningful.

 

Step 4: Compare Different Locations

 

One of the most useful ways to use the TM-207 is comparative measurement.

 

For example:

 

Location A: Open rooftop

Location B: Near a taller building

Location C: Area partially shaded by rooftop equipment

 

Comparing the readings can quickly show how surrounding conditions affect available solar radiation.

 

Step 5: Compare Different Angles

 

Solar panels receive different amounts of solar radiation depending on their orientation relative to the sun.

 

The TM-207 can be used to compare irradiance readings at different angles.

 

This can provide useful field information when assessing panel positioning or investigating an existing installation.

 

It should be used as a measurement aid alongside proper solar PV system design practices rather than as the sole method for determining final system design.

 

Step 6: Check for Shading

 

Shading can come from:

 

Trees

 

Adjacent buildings

 

Water tanks

 

Antennas

 

Rooftop structures

 

HVAC equipment

 

Signboards

 

Take one reading under unobstructed sunlight and another at the affected location.

 

A noticeable difference can help demonstrate the impact of shading at that particular time.

 

Measuring Solar Radiation Through Glass

 

Another useful TM-207 application is glass and solar film comparison.

 

Take a reference measurement where the sensor receives the solar radiation directly.

 

Then take another measurement behind the glass or window film under comparable conditions.

 

The two readings can be compared to evaluate the reduction in measured solar radiation.

 

This method can be useful for:

 

Automotive tint

 

Building window film

 

Solar control glass

 

Glazing comparison

 

Transparent material evaluation

 

Why Not Use a Lux Meter?

 

Lux and solar irradiance are different measurements.

 

A lux meter measures visible illuminance according to human visual response.

 

The TENMARS TM-207 measures solar radiation intensity and provides readings such as W/m².

 

Therefore, a lux meter should not automatically be treated as a substitute when the actual requirement is solar irradiance measurement.

 

Applications in Malaysia

 

Solar irradiance measurement is becoming increasingly relevant as more Malaysian residential, commercial and industrial properties adopt solar PV systems.

 

Potential users include:

 

Solar PV installers

 

Electrical contractors

 

Energy consultants

 

Building inspectors

 

Facility managers

 

Engineering departments

 

Window tint installers

 

Solar film suppliers

 

Universities and technical colleges

 

A portable solar power meter allows these users to obtain quick measurements directly at the site.

 

Practical Solar Measurement Instead of Guesswork

 

Sunlight may look strong, but visual observation does not provide a W/m² measurement.

 

The TENMARS TM-207 Solar Power Meter gives users a simple way to quantify solar radiation and compare different locations, orientations and materials.

 

For technicians who need practical field measurements without a complicated measurement system, the TM-207 can be a useful addition to their testing equipment.

 

Looking for TENMARS TM-207 Solar Power Meter in Malaysia?

 

MTM Precision supplies professional testing and measurement equipment for solar, electrical, environmental, industrial and building applications.

 

Contact us for TENMARS TM-207 Solar Power Meter product information, pricing and availability in Malaysia.

 

Contact MTM Precision

 

MTM Precision Sdn. Bhd.

Showroom & Service Centre

No. 29-1 & 29-2, Jalan Bandar 18,

Pusat Bandar Puchong,

47160 Puchong, Selangor, Malaysia

 

🌐 Website: www.mtmpre.com.my

📧 Email: mtmpre@yahoo.com

📱 WhatsApp: +6016-660 7346


 

15 Aug 2026