Asphalt Temperature Measurement for JKR Road Projects with Myzox AST-10 Malaysia
Asphalt Temperature Measurement for JKR Road Projects with Myzox AST-10 Malaysia
Road construction and pavement maintenance projects in Malaysia require contractors to control and document important site conditions throughout asphalt paving operations.
For contractors working on JKR road projects or other Malaysian road infrastructure projects, asphalt temperature measurement may form part of the applicable construction and QA/QC procedures.
The Myzox AST-10 Digital Asphalt Thermometer is designed for pavement temperature control and, when used with the SE-IN 200 mm needle probe, provides a practical solution for penetration temperature measurement of hot asphalt.
Project personnel should always follow the latest applicable JKR specification, project documents and approved method statement when determining measurement requirements and acceptance criteria.
Why Measure Asphalt Temperature on Road Projects?
Hot mix asphalt changes temperature continuously after production.
The material may lose heat during:
Transportation
Waiting at site
Unloading
Paving
Placement
Rolling
Compaction
Actual temperature measurement gives the site team numerical information about the asphalt at a particular location and stage of construction.
This is more useful for formal QA/QC documentation than relying only on visual observation or elapsed time.
Where Can Temperature Be Checked?
Depending on the applicable project procedure, temperature may be checked at several points.
Asphalt Delivery
A temperature reading may be taken when the hot mix asphalt reaches the construction site.
During Paving
Additional measurements can be performed while the material is being placed.
Behind the Paver
Freshly laid asphalt can be checked at selected locations.
Before Compaction
Temperature measurements can provide useful information before rolling begins.
During Compaction
Further readings may be taken as the pavement continues cooling.
The actual inspection locations and frequency should follow the project's approved requirements.
Myzox AST-10 for Pavement Temperature Control
The Myzox AST-10 supports Type-K thermocouple probes.
The main instrument provides a Type-K measurement range of:
-200掳C to +1,370掳C
Actual measurement capability depends on the connected probe.
For asphalt penetration measurement, Myzox provides the SE-IN Needle Probe.
SE-IN 200 mm Asphalt Probe
The SE-IN features:
Probe length: 200 mm
Measurement range: -50掳C to +650掳C
Type: Penetration needle probe
Myzox identifies this probe as suitable for asphalt measurement.
The probe can be inserted into the asphalt at an appropriate measurement point, allowing temperature to be measured within the material.
Why Is Penetration Measurement Important?
Surface and internal asphalt temperatures may differ.
The exposed pavement surface is affected directly by:
Ambient temperature
Wind
Rain
Moisture
Time after placement
Material below the surface may retain heat differently.
For applications requiring penetration temperature measurement, the SE-IN probe provides direct contact with the asphalt.
Does Myzox AST-10 Determine JKR Compliance?
No.
The AST-10 is a temperature measurement instrument.
It provides a temperature reading but does not independently certify that asphalt complies with a JKR specification or any other project requirement.
Compliance depends on the applicable:
Project specification
Approved asphalt mix
Method statement
Inspection and test plan
QA/QC requirements
Decisions of responsible project personnel
The thermometer provides measurement data that can be used within that process.
What Should Contractors Record?
Depending on project requirements, an asphalt temperature record may include:
Project name
Contract or work section
Date
Time
Road location
Chainage
Asphalt mix
Batch identification
Truck number
Measurement location
Temperature
Paving stage
Weather conditions
Inspector
Remarks
Consistent documentation makes temperature measurements more useful for later review.
Temperature Measurement During Asphalt Delivery
Transportation conditions can influence the temperature of hot mix asphalt before it reaches the project.
Factors include:
Distance from asphalt plant
Traffic
Waiting time
Weather
Truck conditions
Site delays
A delivery temperature measurement gives the contractor actual information about the material at site.
Temperature Measurement Before Compaction
After paving, asphalt continues cooling.
The AST-10 can be used to obtain a penetration temperature reading before compaction where required.
The reading should then be compared with the relevant project requirements.
The AST-10 itself does not determine the correct rolling temperature.
Data Hold for Site Inspection
The AST-10 provides a Data Hold function.
This allows the displayed temperature value to be retained after measurement.
For QA/QC technicians working around active paving operations, this can make recording results more convenient.
MAX and MIN Functions
The AST-10 also provides:
MAX measurement
MIN measurement
Relative measurement mode
These functions provide additional flexibility for repeated temperature measurements.
Can AST-10 Measure Surface Temperature?
The AST-10 can support contact surface temperature measurement with the optional Myzox SE-SU Surface Probe.
The SE-SU has a specified measurement range of:
-20掳C to +400掳C
For asphalt penetration measurement, the SE-IN needle probe remains the relevant choice.
Suitable Road Construction Applications
The AST-10 can be considered for:
Federal road projects
State road projects
Highway construction
Road upgrading
Asphalt resurfacing
Pavement rehabilitation
Road widening
Asphalt overlay
Road maintenance
Infrastructure projects
Its portable design makes it suitable for field temperature measurement across different work locations.
Who Can Use Myzox AST-10?
Potential users include:
Road contractors
Highway contractors
Civil engineering contractors
Asphalt paving companies
QA/QC engineers
Site engineers
Construction consultants
Site supervisors
Field technicians
Road maintenance teams
FAQ: Is Myzox AST-10 JKR Approved?
The AST-10 should not be described as JKR approved unless a specific current approval or requirement explicitly states this.
It is a pavement temperature measurement instrument suitable for asphalt applications.
For JKR projects, contractors should verify the latest project specifications and instrument requirements before use.
FAQ: Can AST-10 Be Used on JKR Road Works?
Where a project requires a suitable Type-K penetration thermometer for asphalt temperature measurement, the AST-10 can be considered based on its specifications.
Final equipment suitability should always be confirmed against the applicable project requirements.
FAQ: What Is the AST-10 Asphalt Probe Range?
The SE-IN 200 mm needle probe has a specified temperature range of:
-50掳C to +650掳C
It is suitable for asphalt measurement.
FAQ: Is AST-10 Suitable for Road QA/QC?
Yes, it can provide asphalt temperature measurements for QA/QC documentation where this measurement method is appropriate.
It should be used together with the project's approved inspection procedures.
Asphalt Temperature Equipment for Malaysian Road Contractors
Road construction quality control depends on accurate measurement, consistent procedures and proper documentation.
For contractors requiring penetration temperature measurement during asphalt paving, the Myzox AST-10 Digital Asphalt Thermometer with SE-IN 200 mm needle probe provides a practical field solution.
It can support temperature monitoring from asphalt delivery through paving and compaction on Malaysian road construction projects.
Myzox Authorized Distributor in Malaysia
MTM Precision Sdn. Bhd. is a Myzox Authorized Distributor in Malaysia, supplying Myzox surveying, civil engineering and road construction instruments.
Contact MTM Precision for information, quotation and availability of the Myzox AST-10 Digital Asphalt Thermometer in Malaysia.
Contact MTM Precision
MTM Precision Sdn. Bhd.
Showroom & Service Centre
No. 29-1 & 29-2, Jalan Bandar 18,
Pusat Bandar Puchong,
47160 Puchong, Selangor, Malaysia.
Website: www.mtmpre.com.my
Email: mtmpre@yahoo.com
WhatsApp: +6016-6607346
Contact us for Myzox AST-10 Digital Asphalt Thermometer Malaysia, road construction QA/QC equipment and asphalt temperature measurement instruments.
16 Aug 2026